Siemens SINUMERIK 810D Commissioning Manual page 86

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

Backing up and Restoring Data
4.2 Backing up and restoring PCU partitions locally
4. Press key <4>.
Your Choice [1, 2, 3, 4, 5, 8, 9]?
"Optional" start
The following steps are only applicable if you wish to change the default settings.
1. To set the maximum number of local backup images (max. 7), press key < 1 >: Configure
Your Choice [1, 2, 9]?
2. To change the preset maximum number of local backup images, select menu 1: Enter a
4-16
The following menu is displayed:
PLEASE SELECT
1 Configure GHOST Parameters
2 Partitions Backup, Mode LOCAL
3 Partitions Restore, Mode LOCAL
4 Partition E (only Windows) Restore, Mode
LOCAL
8 Delete Image
9 Back to previous Menu
GHOST Parameters
The following menu is displayed:
GHOST Connection Mode: LOCAL
Maximum Backup Images: 1
Current Backup Images: 0
PLEASE SELECT
1 Configure GHOST Parameters
2 Partitions Backup, Mode LOCAL
9 Back to previous Menu
new number (max. 7).
Prompt: Save GHOST parameters? Answer Yes.
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0
PCU Basesoftware (IM6)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840diSinumerik 840d