Siemens SINUMERIK 810D Commissioning Manual page 82

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

Backing up and Restoring Data
4.1 Backing up/restoring data with an Ethernet connection
Operations:
1. Install the replacement hard disk in the PCU (installation guide is supplied with new hard
2. Switch on the PG and insert the CD in the drive.
3. Select the "Service menu" [hidden menu entry] in the Boot Manager.
4. Press key <7>: Backup/Restore
5. Enter one of the passwords for authorization levels 0 - 2.
Your Choice [1, 4, 5, 9]?
6. Press key <1>
7. Press key <1>: Configure GHOST parameters
8. Press key <3>: Harddisk Restore from <path name>, Mode PARALLEL
4-12
disk):
– Insert the hard disk into the hinges.
– Insert the connecting cable between hard disk and PCU.
– Secure the hard disk with the 4 knurled-head screws.
– Remove the transport lock: Turn towards "operating" until it engages.
While the PCU is ramping up (after switching the controller off and then on again)
The main menu is displayed:
The system prompts you to enter a password:
The following menu is displayed:
PLEASE SELECT
1 Harddisk Backup/Restore with GHOST
4 Partitions Backup/Restore with GHOST
(locally)
5 ADDM Backup/Restore
9 Back to Main Menu
Set parameters for Norton Ghost:
When this menu is chosen, a message box appears:
You are prompted to check whether a connection exists between the HMI and the
PG/PC. Select the HMI image file to be loaded as the restore image.
– PG/PC:
In a DOS window or at the DOS level enter the command "ghost -lps" to start
Norton Ghost.
– PCU: Start the restore process by acknowledging the message window (Yes).
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0