Configuring the system

2.2 Configuring the operator interface

2.2
Configuring the operator interface
2.2
2.2.1

Storage location of HMI boot screen

Default setting
The Siemens boot screens are stored under the path below on the appropriate PCU, e.g., for
the SINUMERIK 840D controller:
F:\hmi_adv\ib\DATA\0\0\<Auflösung>\0_0.bmp
A directory tree can also be created for manufacturer-specific boot screens. The
manufacturer's screens can then be saved in accordance with the schematic below:
Directory tree of manufacturer-specific boot screens:
F:\oem\ib\DATA\<NckType>\<Resolution>\<Name>.bmp
<NckType>
<Resolution>: 640 or 800 or 1024 dpi
If you want the same screen to be used each time (NCU-independent screen), it can be
saved in the "default" directory in the required resolutions. If you want to be able to use
different screens for different NCUs, they should be saved in the
<NckType>\<Resolution> subdirectories using the appropriate resolution.
Screen name and resolution
<Name>.bmp: The name can be selected freely; only one file is permitted per directory.
The screens must be created with a graphics tool in the resolution indicated by the
subdirectory name and stored in the corresponding directory. The HMI software selects the
screen, depending on the NCK type and the resolution of the available operator panel.
2-10
stands for:
0
840D
2000
810D
5000
840Di
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0