Setup Gui - System - Remote Access - X*Ap Remote - junger D*AP8 FLX Manual

Digital audio processors
Table of Contents

Advertisement

Sync Source Information
You will get detailed information about the measured rates of possible sync sources
System Clock
Sample Rate
Fallback Sample Rate
Fallback Video rate
Sync Source Priority
Choice 1 – 4
Fallback on Sync Error:
AES Select
Accept SDI Generator
Important note! It is not possible to gen lock the SDI generator. The generator will run on its own
internal 27MHz crystal clock.
Video Sync Shift
Offset (lines)
Setup GUI – SYSTEM – Remote Access – X*AP Remote
The X*AP can control multiple D*AP8s one by one and a single D*AP8 may be controlled from multiple
X*APs. This requires a flexible remote concept that allows you to recall pre-set configurations via the X*AP
panel or via the Mobile UI. You can control pre-settings of the EVENTS system via remote access from the
X*AP remote panel or from a Mobile UI on a tablet, a smart phone or even via a browser session from any
PC in the network.
To better understand the possibilities of these settings it is recommended you study the comprehensive
EVENTS system of the D*AP8.
[Follow Source / 44.1 / 48]
[44.1 / 48]
[25 / 29,97 / 30]
[OFF / Internal / Sync-In WCLK / Sync-In AES /
Interface 1 SDI I/O (if fitted) / Sync-In Black Burst/Tri-Level]
[Internal]
If the selected sync source is not available the next source will be
selected. If none of the pre selected sync sources is not available,
the source will fall back to the internal clock oscillator.
[Sync-In AES / Input AES 1/2 BNC ... AES 7/8 BNC]
Select from which physical input the AES sync must be taken.
[ON / OFF]
For rare application you may use the SDI generator (if an SDI I/O
interface is installed) as the sync source. In this case downstream
equipment must be synchronized to the D*AP8.
See INTERFACES > SDI I/O interface > Setup for details
For applications like Dolby E encoding it might be necessary to
move the timing reference point.
[-1023 ... 0 ... 1023]
The number of lines which the reference point can be moved in
either direction.
20