Setup GUI – INTERFACES – MADI Interface – Status / Setup
The implementation of MADI for the D*AP8 is based on the option module O_DAP_MB (BNC) or
O_DAP_MO_MM (MADI optical multi mode fiber) or O_DAP_MO_SM (MADI optical single mode fiber).
Since the D*AP8 is an eight channel processing device not all 64 MADI channels are available for
device I/O. The first 16 channels are available via the MADI local router to the device router.
They appear at the device router pane as MDIN 1 .. 16 and MDOUT 1 ... 16.
These channels can be routed to and from any of the local routing sources MADIRX 1 ... 64
and MADITX 1 ... 64 respectively.
MADI Receiver
Status
Receiver Sample Rate
Receiver Channel Count
Input Channel Status (MDIN) [Transparent / Professional]
Channel Mapping @ 96 kHz
[Locked / Locked-Async / Error]
The timing of the audio decoding is locked to the MADI clock. If the
internal timing of the D*AP8 is different "Locked-Async" is displayed.
[44.1 / 32 / 48 / 88.2 / 96kHz / Unknown]
The measured sample rate from the received MADI stream.
[32 / 56 / 64]
Depends on the upstream MADI transmitter settings.
One may overwrite the input channel status by a set of professional
ones.
[Normal]