Setup Gui - Measurment; Setup Gui - Measurment - Setup - junger D*AP8 FLX Manual

Digital audio processors
Table of Contents

Advertisement

Setup GUI – MEASUREMENT
In the top of the GUI you can read these metering data of a preselected source:
The other two buttons
|| <start> / <pause> / <continue>
x <reset>.
Setup GUI – MEASUREMENT – Setup
Dialog Level (Dialnorm) Measurement:
Beside the ability to measure loudness by above standards, the D*AP8 offers the feature to measure
the long-term A-weighted average level of dialogue within a presentation. A Dolby Digital / Digital plus
consumer decoder (e.g. a Set Top Box) will normalize the output level to -31dBFS by applying a shift
based on the Dialog Level parameter setting. The rule is: -31 - (dialog level value) = shift applied.
Example (dialog level measured = -23dB): -31 - (-23) = -8dB shift applied.
Dialog Intelligence™
Speech Gate
When you click on the little triangle
over here you will get a selection
of the measurement formats available:
This display also shows the duration
of the measurement. If the Speech Gate
is active for the Dialogue Intelligence™
algorithm, the numbers become yellowish
when the measurement has paused
because there is no speech detected for
the moment.
will control the measurement:
Loudness Measurement
Measurement
Mode
Dialogue Level (Dialnorm) Measurement
Dialnorm
Measurement
Channel Select
Dialnorm
Measurement
Algorithm
[OFF / Active]
The Dialog Intelligence™ algorithm developed by
Dolby® Inc. searches for portions of the audio content where
speech is present. Such portions may trigger the loudness
measurement. If it is activated and no speech is detected, the
number display becomes yellowish.
Follows AUDIO PROCESSOR
> Setup > Loudness Mode
[L / R / C / L+R / L+R+C]
[ITU-BS.1770-1 / Leq(A)]
84
D*AP8

Advertisement

Table of Contents
loading

This manual is also suitable for:

D*ap8 tap editionD*ap8 codec edition

Table of Contents