Setup Gui - System - Admin - junger D*AP8 FLX Manual

Digital audio processors
Table of Contents

Advertisement

D*AP8
Setup GUI – SYSTEM – Admin
This Device
Serial Number
Name
Location
Admin / Contact
Graphical User Interface
Authentication
Enable
Change Password for
Password
Repeat
Input fields for information utilized by higher level services.
The electronic serial number. It is printed on a label at the rear of the
device.
Give the device a meaningful name that may be used by name services
and SNMP management.
The place where the D*AP8 is located.
E-mail address of a person in charge.
[Onair max / Preset max, Onair max / Preset min,
Onair min / Preset max, Last Used]
Defines the appearance of the parameter panes in the ON AIR vs.
the PRESETS area (which one will be visible when you open a page).
To prevent non-authorized people from
changing D*AP8 settings the
administrator may assign passwords for
either the admin and/or an operator. While the admin is allowed to set
everything, an operator is just allowed to load presets. Parameters will be
reset if the operator attempted to change it.
[ON / OFF]
The administrator may turn authentication OFF.
[admin / operator]
Select which password you will set / change
type in a password
Default passwords are: admin (for admin) and operator (for operator).
repeat that password
17