junger D*AP8 FLX Manual page 59

Digital audio processors
Table of Contents

Advertisement

D*AP8
Audio Mixing
Auto Voice Over Mode
Trigger Level (dBFS)
Trigger Delay Time (ms)
Trigger Hold Time (ms)
[
Duck Attack Time (ms)
Duck Release Time (ms)
Look Ahead Time (ms)
Warble Tone
Warble Ton Control Mode
Warble Tone Status
Warble Tone Reversion Mode [Last Valid / Internal / Automatic]
[OFF / ON]
In case of ON, the ducking parameter below will be used by the
receiver to perform the mixing.
[-96 ... 0]
Level of the associated audio channel that will turn on the ducking.
[0 ... 4992]
Time that must elapse before ducking becomes active after the trigger
detects a signal that is above the trigger level.
[0 ... 4992]
Time the ducker stays open after trigger becomes active.
[0 ... 4992]
Time the ducker needs to fully open up.
[0 ... 4992]
Time the ducker needs to fully close.
[0 ... 85]
Time to look in advance for the level in the associated channel.
Warble tone is a BBC invention to encode the volume and PAN values
into one audio track while the other track carries the narrators voice
signal.
[OFF / ON]
[Unknown / Not Available / Not Valid / Valid]
55