G.1 MISCELLANEOUS
FIRMWARE
BOOT
VERSION
PROGRAM
VERSION
1.61
2.35
1.62
2.35
1.70
2.35
1.72
2.35
G
G-2
CHANGES DESCRIPTION
COMMUNICATIONS
Configuration:
LED Reset by communications using the configurable logic
METERING
Monitoring of phasor measurements in module and argument
REGISTER
Snapshot Events:
Possibility of reading the Snapshot events in Binary and ASCII
format via ModBus
Oscillography:
The oscillography function has been improved to offer the
possibility of creating up to a maximum of 20 oscillography records,
with possibility to create concatenated oscillographies.
Oscillography records can be obtained via communications using
serial messaging (ModBus) or Ethernet (TCP/IP or TFTP).
Fault Report:
This version incorporates the tool to visualize and store the
information from the last ten faults produced. This report can be
shown on the relay display. The fault report will be available on the
relay display and via communications, either on ModBus (serial) or
TCP/IP.
Data Logger:
It allows registering 16 channels among all the available analog
measures in the relay. The information provided by the data logger
can be obtained via TCP/IP.
USER INTERFACE
Fault Report screen on HMI:
Fault report information on display, selectable by setting
WEB SERVER
Web server tool has been upgraded to provide visualization of:
Snapshot Events
Control Events
Alarms
Oscillography
Fault report
Data Logger
Metering
Internal file management enhancement.
IP Address maintenance after firmware upgrading.
Latched Virtual Inputs maintenance after powering off and on the
relay.
Multilingual relay (French and English available)
COMMUNICATIONS
Multimaster DNP (3 masters)
METERING
Measurement enhancement
PROTECTION
Sensitive Directional Power unit is included (32)
REGISTER
Snapshot Events: Possibility to be enabled and disabled by setting.
In previous versions snapshot event generation was enabled by
default and fixed for all elements.
Using the "config file converter" tool the snapshot event settings will
be included but to their default value (disabled), user must set the
snapshot event generation to the desired value. Notice that having
snapshot event to disabled no internal signals will be recorded in
the snapshot event buffer.
USER INTERFACE
HMI
Enhanced HMI meeting EnerVista F650 Setup structure.
Multilingual Option available: The relay can be ordered in
languages different from English, the relay always has English as
default
Languages Available now:
French/English (F in ordering code request)
English/English (former ordering code)
ENERVISTA F650 SETUP
Multilingual unit (French and English available).
WEB SERVER
Multilingual visualization of snapshot events, control events,
oscillography, fault recorder, data logger, metering.
F650 Digital Bay Controller
APPENDIX G
MODELS
DATE
ALL
th
April 30
2004
ALL
th
June 24
2004
F650BABF1G0HIF
th
August 5
F650MFDF2G1LOF
2004
F650MFCF1G1LOF
ALL
November
th
26
2004