<DETAILS>
The Details screen provides access to metering values, and date and time related with the event.
The top of the screen displays a legend with the event text, followed by the date and time, the event status (ON or
OFF), and the event index number related to the complete list of events in the relay, for example (1/479). The rest of
information provided by the Details screen corresponds to the relay measures in the moment of the event. Metering
values provided in the events are secondary, and voltage values correspond to phase-to-ground voltage.
4
To navigate this screen the user must follow the legend at the bottom of the screen:
Intro: Meters.
To access the metering values in the moment of the event, the user must press the shuttle key. A new metering screen
will be displayed, containing the primary metering values in the snapshot event, such as:
Phasor Ia Primary
Phasor Ib Primary
Phasor Ic Primary
Line Frequency Primary
Phasor Ig Primary
Phasor Isg Primary
I0 Primary
I1 Primary
Once inside the Metering screen, a new legend will be shown for each event (Intro or ESC: Prev. L-R: Scroll); this
legend indicates that by pressing ESC or the shuttle key, the system will return to the Event Detail screen, and rotating
the shuttle key the user will access all the metering values contained in the metering screen of the considered event.
ESC: Prev.
If the user presses the ESC key from the event detail screen, the system will return to the all events screen.
4-58
R eady LE D O N
D ate: 10/Jun/2005
Tim e: 16:11:08.035
P hasor Ia P rim ary
P hasor Ib Prim ary
P hasor Ic P rim ary
Line Frequency
P hasor Ig Prim ary
P hasor Isg P rim ary
I0 Prim ary
I1 Prim ary
Intro: M eters.
E SC : Prev.
Figure 4–30: SNAPSHOT EVENTS DETAIL SCREEN
Intro: Meters. ESC: Prev.L-R: Scroll.
F650 Digital Bay Controller
S t:O N
(1/479)
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
L-R : S croll.
I2 Primary
Vab Primary
Vbc Primary
Vca Primary
V1 Primary
V2 Primary
V0 Primary
3 Phase Power Factor