GE Multilin F650 Instruction Manual page 532

Hide thumbs Also See for Multilin F650:
Table of Contents

Advertisement

APPENDIX G
FIRMWARE
BOOT
CHANGES DESCRIPTION
VERSION
PROGRAM
VERSION
1.80
2.35
USER INTERFACE
HMI:
ENERVISTA F650 SETUP
WEB SERVER
COMMUNICATIONS
METERING
PROTECTION
REGISTER
1.82
4.00
File system management enhancement in boot code 4.00
Measurements enhancement in 1.82 firmware version
Versions 1.8X can not be upgraded to 2.XX firmware version
without hardware change.
2.20
4.00
USER INTERFACE
ENERVISTA F650 SETUP·
COMMUNICATIONS·
INPUTS/OUTPUTS·
METERING·
PROTECTION·
REGISTER·
GE Multilin
New languages available: Russian and Spanish.
Russian/English (P in ordering code, basic display only)
Spanish/English (S in ordering code)
New languages available: Russian and Spanish.
Passwords included in EnerVista F650 Setup (different from the
HMI ones).
Multilingual visualization of snapshot events, control events,
oscillography, fault recorder, data logger, metering. New
languages available: Russian and Spanish.
Visualization Enhancement.
Modbus TCP communications enhacement.
External CAN interruptions management enhancement.
Decimal point included in PT and CT ratios.
Power Factor measurement enhancement.
Function 48 included.
I2/I1 setting to select the minimum inhibition current level of the
unit .
TOC operation level at 1.03 times the pickup (1.05 in previous
releases).
Neutral units measures management enhancement.
Startup Enhancement.
Time Stamp for switchgear control events enhancement.
- Data Logger visualization changes.·
- File name available in "Config file converter" tool.
- DNP Scale factor correction.·
- IRIGB synchronization:
- Date and time synchronization available.
- 980 ms delay correction.
- Inputs Activation/Deactivation correction.·
- Voltage threshold setting range from 20 to 230 Vdc.·
- Debounce time settings:
- Timestamp before debounce time
- Setting range from 1 to 50 ms.
- Power calculations using ARON method.·
- New measurements provided when using Delta connection
and VN as auxiliary voltage input:
- Neutral voltage available.
- Phase to ground voltages available.
- Single phase power measurements available.
- Neutral, ground and sensitive ground directional units
available with delta connection and VN as auxiliary voltage
input.·
- Minor changes in Forward Power elements.
- Ground current available in Fault report.·
- Corrected 150 ms delay in Snapshot events measurements.
F650 Digital Bay Controller
G.1 MISCELLANEOUS
MODELS
DATE
ALL
st
March 1
2005
ALL
October 17th
2005
All models,
November
excepting Options 4
25th 2005
and 5 for I/O boards.
Option 6 for IEC
61850 protocol
G-3
G

Advertisement

Table of Contents
loading

Table of Contents