Setting A Time Range - Edge-Core ECS4510-12PD Web Management Manual

12-port gigabit ethernet layer 2 switch
Hide thumbs Also See for ECS4510-12PD:
Table of Contents

Advertisement

Chapter 12
| Security Measures
Access Control Lists

Setting A Time Range

Use the Security > ACL (Configure Time Range) page to sets a time range during
which ACL functions are applied.
Command Usage
If both an absolute rule and one or more periodic rules are configured for the same
time range (i.e., named entry), that entry will only take effect if the current time is
within the absolute time range and one of the periodic time ranges.
Parameters
These parameters are displayed:
Add
Time-Range Name – Name of a time range. (Range: 1-16 characters)
Add Rule
Time-Range – Name of a time range.
Mode
Absolute – Specifies a specific time or time range.
Start/End – Specifies the hours, minutes, month, day, and year at which
to start or end.
Periodic – Specifies a periodic interval.
Start/To – Specifies the days of the week, hours, and minutes at which
to start or end.
Web Interface
To configure a time range:
1.
Click Security, ACL.
2.
Select Configure Time Range from the Step list.
3.
Select Add from the Action list.
4.
Enter the name of a time range.
5.
Click Apply.
– 290 –