Configuring Telnet Settings

Use the System > Telnet menu to configure parameters for accessing the CLI over a
Telnet connection. You can access the onboard configuration program over the
network using Telnet (i.e., a virtual terminal). Management access via Telnet can be
enabled/disabled and other parameters set, including the TCP port number, time
outs, and a password. Note that the password is only configurable through the CLI.)
These parameters can be configured via the web or CLI interface.
Parameters
The following parameters are displayed:
Telnet Status – Enables or disables Telnet access to the switch.
(Default: Enabled)
TCP Port – Sets the TCP port number for Telnet on the switch. (Default: 23)
Max Sessions – Sets the maximum number of Telnet sessions that can
simultaneously connect to this system. (Range: 0-8)
A maximum of eight sessions can be concurrently opened for Telnet and
Secure Shell (i.e., both Telnet and SSH share a maximum number or eight
sessions).
Login Timeout – Sets the interval that the system waits for a user to log into
the CLI. If a login attempt is not detected within the timeout interval, the
connection is terminated for the session. (Range: 10-300 seconds;
Default: 300 seconds)
Exec Timeout – Sets the interval that the system waits until user input is
detected. If user input is not detected within the timeout interval, the current
session is terminated. (Range: 60-65535 seconds; Default: 600 seconds)
Password Threshold – Sets the password intrusion threshold, which limits the
number of failed logon attempts. When the logon attempt threshold is
reached, the system interface becomes silent for a specified amount of time
(set by the Silent Time parameter) before allowing the next logon attempt.
(Range: 1-120; Default: 3 attempts)
Silent Time – Sets the amount of time the management interface is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 1-65535 seconds; Default: Disabled)
Note: Password checking can be enabled or disabled for login to the console
connection (see the "login" command in the CLI Reference Guide). You can select
authentication by a single global password as configured for the password
command, or by passwords set up for specific user-name accounts. The default is
for local passwords configured on the switch.
Chapter 3
– 87 –
| Basic Management Tasks
Configuring Telnet Settings