B Troubleshooting; Problems Accessing The Management Interface; Table 38: Troubleshooting Chart - Edge-Core ECS4510-12PD Web Management Manual

12-port gigabit ethernet layer 2 switch
Hide thumbs Also See for ECS4510-12PD:
Table of Contents

Advertisement

B

Problems Accessing the Management Interface

Troubleshooting

Table 38: Troubleshooting Chart

Symptom
Cannot connect using web
browser or SNMP software
Cannot access the on-
board configuration
program via a serial port
connection
Forgot or lost the password
Action
Be sure the switch is powered up.
Check network cabling between the management station and the
switch.
Check that you have a valid network connection to the switch and
that the port you are using has not been disabled.
Be sure you have configured the VLAN interface through which the
management station is connected with a valid IP address, subnet
mask and default gateway.
Be sure the management station has an IP address in the same
subnet as the switch's IP interface to which it is connected.
If you are trying to connect to the switch via the IP address for a
tagged VLAN group, your management station, and the ports
connecting intermediate switches in the network, must be
configured with the appropriate tag.
Be sure you have set the terminal emulator program to VT100
compatible, 8 data bits, 1 stop bit, no parity, and the baud rate set to
115200 bps). For information on using the command line interface,
see the CLI Reference Guide.
Check that the null-modem serial cable conforms to the pin-out
connections provided in the Installation Guide.
Contact your local distributor.