Siemens siprotec 7SA522 User Manual page 584

Distance protection
Hide thumbs Also See for siprotec 7SA522:
Table of Contents

Advertisement

Appendix
Addr.
Setting Title
3148
3I0p Telep/BI
3149
3I0p SOTF-Trip
3150
3I0p InrushBlk
3151
IEC Curve
3152
ANSI Curve
3153
LOG Curve
3154
3I0p Startpoint
3160
POLARIZATION
3162
Dir. ALPHA
3163
Dir. BETA
3164
3U0>
3165
IY>
3166
3U2>
3167
3I2>
3170
2nd InrushRest
3171
Imax InrushRest
3172
SOTF Op. Mode
3173
SOTF Time DELAY Earth fault overcur-
3201
FCT Telep. E/F
3202
Line Config.
3203
Send Prolong.
3207
Delay for alarm
3208
Release Delay
3209
TrBlk Wait Time
B-12
Function
Setting Options
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
NO
rent
YES
Earth fault overcur-
Normal Inverse
rent
Very Inverse
Extremely Inverse
Long time inverse
Earth fault overcur-
Inverse
rent
Short Inverse
Long Inverse
Moderately Inverse
Very Inverse
Extremely Inverse
Definite Inverse
Earth fault overcur-
Logarithmic inverse
rent
Earth fault overcur-
1.0..4.0
rent
Earth fault overcur-
with U0 and IY (dual polar-
rent
ized)
with IY (transformer star
point current)
with U2 and I2 (negative
sequence)
0..360 °
Earth fault overcur-
rent
0..360 °
Earth fault overcur-
rent
Earth fault overcur-
0.5..10.0 V
rent
Earth fault overcur-
0.05..1.00 A
rent
Earth fault overcur-
0.5..10.0 V
rent
Earth fault overcur-
0.05..1.00 A
rent
Earth fault overcur-
10..45 %
rent
Earth fault overcur-
0.50..25.00 A
rent
Earth fault overcur-
with Pickup (non-directional)
rent
with Pickup and direction
0.00..30.00 sec
rent
Teleprotection for
ON
Earth fault overcurr.
OFF
Teleprotection for
Two Terminals
Earth fault overcurr.
Three Terminals
Teleprotection for
0.00..30.00 sec
Earth fault overcurr.
Teleprotection for
0.00..30.00 sec
Earth fault overcurr.
Teleprotection for
0.000..30.000 sec
Earth fault overcurr.
Teleprotection for
0.00..30.00 sec
Earth fault overcurr.
Default Setting
NO
Instantaneous trip via Teleprot./BI
NO
Instantaneous trip after SwitchOnTo-
Fault
NO
Inrush Blocking
Normal Inverse
IEC Curve
Inverse
ANSI Curve
Logarithmic inverse
LOGARITHMIC Curve
1.1
Start point of inverse characteristic
with U0 and IY (dual polar-
Polarization
ized)
338 °
ALPHA, lower angle for forward direc-
tion
122 °
BETA, upper angle for forward direc-
tion
0.5 V
Min. zero seq.voltage 3U0 for polariz-
ing
0.05 A
Min. earth current IY for polarizing
0.5 V
Min. neg. seq. polarizing voltage 3U2
0.05 A
Min. neg. seq. polarizing current 3I2
15 %
2nd harmonic ratio for inrush restraint
7.50 A
Max.Current, overriding inrush
restraint
with Pickup and direction
Instantaneous mode after Switch-
OnToFault
0.00 sec
Trip time delay after SOTF
ON
Teleprotection for Earth Fault O/C
Two Terminals
Line Configuration
0.05 sec
Time for send signal prolongation
10.00 sec
Unblocking: Time Delay for Alarm
0.000 sec
Time Delay for release after pickup
0.04 sec
Transient Block.: Duration external flt.