Advertisement

Quick Links

7XV75 Test Switch
Notes on Safety
This catalogue contains notes that must be adhered to for your own personal safety and to avoid damage to property.
However, it does not constitute a complete description of all safety measures required for installation, service, and mainte-
nance of the equipment (module, device) in question. Details are to be taken from the device manual and those are manda-
tory.
WARNING
Danger of severe personal injury or substantial damage to property
Hazardous voltages may occur in devices and modules during operation depending on the design and appli-
cation.
 Always observe the instructions given in "Qualified Electrical Engineering Personnel" below.
Qualified Electrical Engineering Personnel
Only qualified electrical engineering personnel may commission and operate the equipment (module, device) described in
this document. Qualified electrical engineering personnel in the sense of this document are people who can demonstrate
technical qualifications as electrical technicians. These persons may commission, isolate, ground and label devices, sys-
tems and circuits according to the standards of safety engineering.
Use as Prescribed
The equipment (device, module) may only be used for such applications as set out in the catalogs and the technical de-
scription, and only in combination with third-party equipment recommended and approved by Siemens.
Problem-free and safe operation of the product depends on the following:
Proper transport
Proper operation and maintenance
Proper storage, setup, and installation
WARNING
Danger of death, personal injury or substantial property damage
Non-observance of the following measures can result in death, personal injury or substantial property
damage.
 The equipment must be grounded at the grounding terminal before any connections are made.
If you require further information, or if particular problems occur that are not handled in sufficient depth in the instructions
of the respective product, you can request help through your local Siemens Office or representative.
Statement of Conformity
Low-voltage Directive 2014/35/EU
RoHS Directive 2011/65/EU R
The conformity is based on the compliance with
the following harmonized standards
EN 50581 and EN 60255-27
Further standards
IEC 60255, VDE 0435
1
7XV75 Test Switch
Siemens AG
March 2021

Advertisement

Table of Contents
loading

Summary of Contents for Siemens 7XV75

  • Page 1  The equipment must be grounded at the grounding terminal before any connections are made. If you require further information, or if particular problems occur that are not handled in sufficient depth in the instructions of the respective product, you can request help through your local Siemens Office or representative. Statement of Conformity...
  • Page 2: Mode Of Operation

    7XV75 Test Switch Application Mode of operation The test switch serves in the test- The 7XV75 test switch serves for ing of protection devices using testing protection devices includ- secondary injection test sets. ing C.T. circuits and command contacts. With the help of the...
  • Page 3: Technical Data

    7XV75 Test Switch Technical data General device data Rated operating voltage V 250 V AC/DC Rated operating current I Max 5 A Test current capacity for 1 s 150 A for 10 s 60 A Continuous current 20 A Overvoltage category, IEC 60255-27...
  • Page 4 7XV75 Test Switch Technical data Voltage Terminals Recommended use of the screwed terminals Stripping length (when used without conductor sleeve) L = 10 mm (0,39 in) or L = 12 mm (0,47 in); max. wire cross-section AWG 16 (1.5 mm...
  • Page 5 7XV75 Test Switch Connection Diagram for 7XV7500-0CA00 Test Switch Siemens AG March 2021...
  • Page 6 7XV75 Test Switch Connection Diagram for 7XV7501-0CA00 Test Switch Typically not for distance protection or if used please consider the switch order of S1 and S2 (Operation->Test: S2 (I) – S1 (V); Test->Operation: S1 (V) – S2 (I)). Siemens AG...
  • Page 7 7XV75 Test Switch Connection Diagram for 7XV7502-0CA00 Test Switch Siemens AG March 2021...
  • Page 8 7XV75 Test Switch Connection Diagram for 7XV7503-0CA00 Test Switch Typically not for distance protection or if used please consider the switch order of S1 and S2 (Operation->Test: S2 (I) – S1 (V); Test->Operation: S1 (V) – S2 (I)). Siemens AG...
  • Page 9 7XV75 Test Switch Connection Diagram for 7XV7506-0CA00 three-stage Test Switch Siemens AG March 2021...
  • Page 10 7XV75 Test Switch Connection Diagram for 7XV7507-0CA00 Test Switch Siemens AG March 2021...
  • Page 11 7XV75 Test Switch Connection Diagram for 7XV7508-0CA00 Test Switch Siemens AG March 2021...
  • Page 12: Front View

    7XV75 Test Switch Dimension drawings in mm / inch Side view Front view Rear view of 7XV750X Panel cutout Siemens AG March 2021...
  • Page 13 Siemens AG or of quired for the products listed in ties except where current Ger- other suppliers. this catalog.

Table of Contents