Operating instructions
SITRANS L
Point level switches
LVS100/LVS200
Edition
01/2019
www.siemens.com/processautomation

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS L Series

  • Page 1 Operating instructions SITRANS L Point level switches LVS100/LVS200 Edition 01/2019 www.siemens.com/processautomation...
  • Page 3 Introduction Description Operating SITRANS L Installation Point Level Switches SITRANS LVS100/200 Connecting Maintenance Operating Instructions Technical data Dimension drawings Certificates and support 7ML5735 (SITRANS LVS100 Standard) 7ML5731 (SITRANS LVS200 Standard) 7ML5732 (SITRANS LVS200 Short fork) 7ML5733 (SITRANS LVS200 Pipe extension) 7ML5734 (SITRANS LVS200 Cable extended) 01/2019 A5E44839609-AA...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Table of contents Introduction ..............................5 Purpose of this documentation ....................5 Description ..............................6 SITRANS LVS100, SITRANS LVS200 - standard version ............6 SITRANS LVS200 - liquid/solid interface version ..............6 SITRANS LVS200 - pipe extension version ................6 Product features ........................
  • Page 6 Table of contents Technical data ............................38 Dimension drawings ..........................42 SITRANS LVS100 ........................42 Zone classification ......................... 43 SITRANS LVS200 ........................44 Zone classification ......................... 45 SITRANS LVS200 Forks ......................46 Certificates and support ........................... 47 Technical support ........................47 Certificates ..........................
  • Page 7: Introduction

    Introduction Purpose of this documentation These instructions contain all information required to commission and use the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation. The instructions are aimed at persons mechanically installing the device, connecting it electronically, configuring the parameters and commissioning it, as well as service and maintenance engineers.
  • Page 8: Description

    Description The SITRANS LVS100 and SITRANS LVS200 are available in a standard version, with the SITRANS LVS200 offering two additional versions. SITRANS LVS100, SITRANS LVS200 - standard version SITRANS LVS100/200 standard version is a vibrating level switch that detects high or low levels of dry bulk solids in bins, silos, or hoppers.
  • Page 9: Product Features

    Description 2.4 Product features Product features ● High resistance to mechanical forces ● Strong vibration resistance to high bulk material loads ● Rotatable enclosure ● LVS100: R 1½" (BSPT); 1¼" NPT (Taper) threaded connection ● LVS200: Stainless steel 1½” NPT or R 1½” (BSPT) threaded connection, or R 2" (BSPT) or NPT sliding sleeve.
  • Page 10 Description 2.6 Principle of operation WARNING Chemical compatibility Materials of construction are chosen based on their chemical compatibility (or inertness) for general purposes. For exposure to specific environments, check with chemical compatibility charts before installing. SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 11: Operating

    Operating Note The signal output and test options listed below apply only to specific power supply options. Signal output delay Universal voltage (DPDT) model The signal output can be delayed and is adjustable from 0 to 30 seconds. Turn the potentiometer clockwise to increase the delay time.
  • Page 12 Operating 3.2 Test function NAMUR model ① Test button ② Electronic module ③ Diagnostic LED ④ Sensitivity adjustment: B = factory setting A = decreased sensitivity SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 13 Operating 3.2 Test function 8/16 or 4 to 20 mA model ① Test button ② Sensor switches at high level Fail-safe function will default to full signal Sensor switches at low level Fail-safe function will default to empty signal ③ Diagnostic LED ④...
  • Page 14: Vibration Amplitude Diagnosis

    Operating 3.3 Vibration amplitude diagnosis Vibration amplitude diagnosis NAMUR module (IEC 60947-5-6) and 8/16 mA or 4 to 20 mA model Measurement quality is related to the vibration amplitude of the fork. The diagnostic LED indicates the quality of the vibration being sent to the LVS200 electronics. ●...
  • Page 15: Buildup Detection (8/16 Ma Or 4 To 20 Ma Version)

    Operating 3.5 Buildup detection (8/16 mA or 4 to 20 mA version) Buildup detection (8/16 mA or 4 to 20 mA version) With the 4 to 20 mA setting, you can recognize material buildup on the fork using a PLC or data logger.
  • Page 16: Installation

    Installation Mounting ● Installation shall be performed by qualified personnel and in accordance with local governing regulations. ● Do not bend, shorten or extend the tines. ● Position the tines using a 50 mm open-end wrench when installing the process connection (do not turn the housing).
  • Page 17 Installation 4.1 Mounting WARNING LVS200 • Installation in Zone 0 (electronics: NAMUR): The intrinsic safe supply circuit must have galvanic isolation to a non- intrinsically safe area. Otherwise, provide protection for the device against lightning strikes (see EN 60079-14). • Power supply (electronics: NAMUR): Intrinsically safe protection is only valid when connected to a certified intrinsically safe power supply.
  • Page 18 Installation 4.1 Mounting SITRANS LVS100/200 is normally mounted into the vessel top for full detection, or through the tank wall at the detection level, for full, demand, or empty detection. Position tines vertically to avoid product buildup: use a 50 mm open-end wrench to turn the process connection until the tine orientation marking faces up or down.
  • Page 19: Process Cautions

    Installation 4.2 Process cautions Process cautions CAUTION Falling material Locate SITRANS LVS100/200 out of path of falling material Protect shaft and tines from falling material SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 20: Temperature Isolator Option (Lvs100/200)

    Installation 4.3 Temperature isolator option (LVS100/200) Temperature isolator option (LVS100/200) When installed with the temperature isolator option, SITRANS LVS100/200 can operate in higher ambient temperatures. ① Installed without temperature isolator, process connection at surface ② Installed without temperature isolator, process connection above surface ③...
  • Page 21 Installation 4.3 Temperature isolator option (LVS100/200) Process temperature (LVS200) ① Installed without temperature isolator, process connection at surface ② Installed without temperature isolator, process connection above surface ③ Installed with temperature isolator option SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 22: Connecting

    Connecting WARNING Wiring safety precautions • Open SITRANS LVS100/200 only when supply voltage is switched off. • All field wiring must have insulation suitable for at least 250 V AC. • A disconnect switch must be in close proximity to the equipment and within easy reach of the operator.
  • Page 23: Connection Recommendations

    Connecting 5.1 Connection recommendations Conduit systems for FM and CSA (Dust and Gas Hazardous Locations) General requirements: In addition the regulations of the country must be observed. The used flameproof seals and blanking elements must have an adequate type approval and a temperature range of at least -40 to 80 °C (-40 to 176 °F).
  • Page 24 Connecting 5.2 Precautions Universal voltage (DPDT relay) (LVS100) ① ④ alarm output relays ② ⑤ sensitivity adjustment fuses: max. 10 A, fast or slow, HBC, 250 V B = factory setting, A = decreased sensitivity ③ ⑥ FSH/FSL adjustment protective earth terminal SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 25 Connecting 5.2 Precautions Universal voltage (SPDT relay) (LVS200) ① ④ alarm output relay ② ⑤ FSH/FSL adjustment fuses: max. 10 A, fast or slow, HBC, 250 V ③ ⑥ sensitivity adjustment protective earth terminal B = factory setting, A = decreased sensitivity Universal voltage (DPDT relay) (LVS200) ①...
  • Page 26 Connecting 5.2 Precautions 3-wire PNP (LVS200) ① ② load 2-wire (LVS200) ① NAMUR IEC 60947-5-6 (LVS200) SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 27 Connecting 5.2 Precautions 8/16 mA or 4 to 20 mA (LVS200) SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 28: Power Supply Specifications

    Connecting 5.3 Power supply specifications Power supply specifications Universal voltage (DPDT relay) (LVS100) terminal 1: L terminal 2: N 19 to 230 V AC, ± 10 %, 50 to 60 Hz, 22 VA terminal 1: + terminal 2: - 19 to 40 V DC, ± 10 %, 2 W Universal voltage (SPDT relay) (LVS200) terminal 1: L...
  • Page 29: Sensitivity

    Connecting 5.4 Sensitivity Sensitivity If the measured material tends to cake or build up, the sensitivity adjustment switch can be set to position A to decrease the sensitivity of the probe (factory setting is position B). The sensitivity for interface applications should be set to position B, while the setting for high-flow applications should be position A.
  • Page 30: Switching Logic

    Connecting 5.5 Switching logic LVS200 ① FSH/FSL adjustment or High/Low Alarm setting (NAMUR) ② sensitivity adjustment: B = factory setting A = decreased sensitivity Switching logic Probe uncovered Model Signal output failsafe - low Signal output failsafe - high LVS100 DPDT relay LVS200 SPDT relay...
  • Page 31 Connecting 5.5 Switching logic Model Signal output failsafe - low Signal output failsafe - high 8/16 mA I = 16 mA I = 8 mA Signal Output LED Low alarm setting High alarm setting NAMUR IEC 60947-5-6 I < 1 mA I >...
  • Page 32: Sitrans Lvs200 Pipe Extension Version

    Connecting 5.6 SITRANS LVS200 Pipe extension version Model Signal output failsafe - low Signal output failsafe - high 2-wire 8/16 mA I = 8 mA I = 16 mA Signal Output LED Low alarm setting High alarm setting NAMUR IEC 60947-5-6 I >...
  • Page 33: Extension Tube Dimensions

    Connecting 5.6 SITRANS LVS200 Pipe extension version 5.6.2 Extension tube dimensions Version with G1" (DIN ISO 228-1) thread ① Pipe length x LVS200 (7ML5733 with short fork, application type 2, liquids/solids interface): X = L - 180 mm (X = L - 7.1") LVS200 (7ML5733 with standard fork, application type 1): X = L - 250 mm (X = L - 9.8") LVS200 (7ML5733 with standard fork, application type 1 and z option K05 or G01, enhanced sensitivity): X = L - 275 mm (X = L - 10.8")
  • Page 34 Connecting 5.6 SITRANS LVS200 Pipe extension version Version with 1" (ANSI B 1.20.1.) NPT thread ① Pipe length x LVS200 (7ML5733 with short fork, application type 2, liquids/solids interface): X = L - 190 mm (X = L - 7.5") LVS200 (7ML5733 with standard fork, application type 1): X = L - 260 mm (X = L - 10.2") LVS200 (7ML5733 with standard fork, application type 1 and z option K05 or G01, enhanced sensitivity): X = L - 285 mm (X = L - 11.2")
  • Page 35: Assembly

    Connecting 5.6 SITRANS LVS200 Pipe extension version 5.6.3 Assembly Suggested tools: ● medium Phillips or 6 to 8 mm (¼”) flat screwdriver ● 3 mm (1/8”) flat screwdriver ● wire cutters ● wire strippers ● terminal crimper ● 36 mm open end wrench ●...
  • Page 36 Connecting 5.6 SITRANS LVS200 Pipe extension version 4. Line up the fork and the tine orientation marking as shown in dimension drawing. (The tine orientation marking on the process connection is to identify the vertical orientation of the fork.) ① Earth cable (green/yellow) 5.
  • Page 37 Connecting 5.6 SITRANS LVS200 Pipe extension version 10. Crimp the ring terminal 4 mm (0.19") to sensor earth cable. ① 3 mm (1/8”) screw driver ② Cable ties 11. Connect electronics module and terminal connection board. Be sure that all terminals are tight.
  • Page 38: Assembly Overview Drawing

    Connecting 5.6 SITRANS LVS200 Pipe extension version 5.6.4 Assembly overview drawing ① ⑦ Thread G1” or 1" NPT (use appropriate thread sealant) ② ⑧ Process connection Tine orientation marking ③ ⑨ Enclosure assembly Process thread 1 ½” NPT (taper) or R 1 ½” (BSPT) ④...
  • Page 39: Maintenance

    Please note the following: ● The user is responsible for all changes and repairs made to the device. ● All new components must be provided by Siemens. ● Restrict repair to faulty components only. ● Do not re-use faulty components.
  • Page 40: Technical Data

    Technical data Note Device specifications Siemens makes every attempt to ensure the accuracy of these specifications but reserves the right to change them at any time. Power LVS100 19 to 230 V AC, ±10 %, 50 to 60 Hz, 22 VA / 19 to 40 V DC, ±10 %, 2 W...
  • Page 41 316Ti (1.4571)/ 316L (1.4581) (PTFE coated tines are available upon special request. Con- tact your local Siemens representative for or- dering information.) Enclosure construction epoxy-coated aluminum conduit entry 2 x M20x1.5, or 2 x ½” NPT...
  • Page 42 Environmental location indoor/outdoor altitude max. 2000 m (6562 ft) ambient tempera- –40 to +60 °C (–40 to +140 °F) ture relative humidity 0 to 100% (suitable for outdoor: ingress protection: Type 4X/NEMA 4X/IP66) overvoltage cate- gory pollution degree Process Temperature All approvals ex- –40 to +150 °C (–40 to +302 °F) cept CSA Class II,...
  • Page 43 Note SITRANS LVS200 can be installed with an optional temperature isolator extension. The isolator increases the distance of the electronics from the process surface, thus allowing for a higher ambient temperature. See “Temperature Isolator Option (LVS100/200) (Page 18)” for more information Note Pressure information for hazardous areas The device construction allows over-pressure up to 30 bar.
  • Page 44: Dimension Drawings

    Dimension drawings SITRANS LVS100 ① ④ Customer supplied process flange 170 to 4000 mm (6.69 to 157"): customer-specified rigid extension ② ⑤ Threaded bushing [max. temp. 125 mm (4.92"): standard fork +80°C(+176°F)] ③ ⑥ Tine orientation marking Tine SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 45: Zone Classification

    Zone classification EPL (IEC-Ex) Category (ATEX) Zone EPL (IEC-Ex) Category (ATEX) Zone SITRANS LVS100/200 Operating Instructions, 01/2019, A5E44839609-AA...
  • Page 46: Sitrans Lvs200

    SITRANS LVS200 ① Tine ② Customer supplied process flange ③ Optional sliding bushing* ④ Threaded bushing [max. temp. +80°C (+176°F)] ⑤ Tine orientation marking ⑥ Compact solids/liquids interface model: 165 mm (6.5"): Compact standard version: 230 mm (9.0") Customer-specified rigid extension: 300 to 4000 mm (11.81 to 157") ⑦...
  • Page 47: Zone Classification

    Note The clamping screws of the sliding bushing must be tightened to 10 Nm. Zone classification Universal voltage Relay SPDT NAMUR IEC 60945-5-6 (Intrinsically Safe) Universal Voltage Relay DPDT 8/16 mA or 4-20 mA (Intrinsically Safe) 3-wire PNP 2 wire without contact 8/16 mA or 4-20 mA (Non-intrinsically safe) EPL (IECEx) Da...
  • Page 48: Sitrans Lvs200 Forks

    SITRANS LVS200 Forks ① Standard version ② TriClamp version ③ Cable version ④ Standard fork: 170 mm (6.69") Low density fork: 195 mm (7.68") Liquid/solid (short) fork: 100 mm (3.94") ⑤ Compact solids/liquids interface model: 165 mm (6.5") Compact standard version: 230 mm (9.0") Customer-specified rigid extension: 300 to 4000 mm (11.81 to 157") Note Cable version with Liquids/solids interface model option length to 7000 mm (275.59")
  • Page 49: Certificates And Support

    In addition to our documentation, Siemens provides a comprehensive support solution at: ● Partner (http://www.automation.siemens.com/partner) Personal contact If you have additional questions about the device, please contact your Siemens personal contact at: ● Support request (http://www.siemens.com/automation/support-request) To find the personal contact for your product, go to "All Products and Branches" and select "Products &...
  • Page 50: Index

    Index Certificates, 47 Compact Operating Instructions, 47 Customer Support, (Refer to Technical support) Documentation, 47 Hotline, (Refer to Support request) Instructions and manuals, 47 Manuals, 47 Operating Instructions, 47 Service, 47 Service & Support, 47 Internet, 47 Support, 47 Support request, 47 Technical data, 38 Technical support, 47 Partner, 47...
  • Page 52 For more information Level measurement: www.siemens.com/level Weighing and batching systems: www.siemens.com/weighing Siemens AG Process Industries and Drives Process Automation 76181 Karlsruhe Germany © Siemens AG 2019 Subject to change without prior notice Printed in Canada A5E44839609-AA...

Table of Contents