Siemens siprotec 7SA522 User Manual page 588

Distance protection
Hide thumbs Also See for siprotec 7SA522:
Table of Contents

Advertisement

Appendix
Addr.
Setting Title
3515
SYNC-CHECK
3516
Usync> U-line<
3517
Usync< U-line>
3518
Usync< U-line<
3519
OVERRIDE
3530
Op.mode with MC
3531
MC maxVolt.Diff
3532
MC maxFreq.Diff
3533
MC maxAngleDiff
3535
MC SYNCHR
3536
MC Usyn> Uline<
3537
MC Usyn< Uline>
3538
MC Usyn< Uline<
3539
MC O/RIDE
3701
Uph-e>(>)
3701
FCT Uphase-e
3702
Uph-e>
3703
T Uph-e>
3704
Uph-e>>
3705
T Sen-Imp(Uphe)
3721
3U0>(>) (or Ux)
3722
3U0>
3723
3U0 Reset Ratio
3724
T 3U0
3725
T Sen-Imp 3UO
3802
START
3805
Paral.Line Comp
3806
Load Compensat.
3901
FCT BreakerFail
B-16
Function
Setting Options
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
with consideration of CB
Voltage Check
closing time
without consideration of CB
closing time
Synchronism and
1.0..40.0 V
Voltage Check
Synchronism and
0.03..2.00 Hz
Voltage Check
2..60 °
Synchronism and
Voltage Check
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Synchronism and
YES
Voltage Check
NO
Voltage Protection
OFF
Alarm Only
ON
Voltage Protection
OFF
Alarm Only
ON
Voltage Protection
1.0..170.0 V
Voltage Protection
0.00..30.00 sec
Voltage Protection
1.0..170.0 V
Voltage Protection
0.05..0.50 sec
Voltage Protection
OFF
Alarm Only
ON
Voltage Protection
1.0..220.0 V
Voltage Protection
0.50..0.95
Voltage Protection
0.00..30.00 sec
Voltage Protection
0.05..0.50 sec
Fault Locator
Pickup
TRIP
Fault Locator
NO
YES
Fault Locator
NO
YES
Breaker Failure
ON
OFF
Default Setting
YES
Live bus / live line and Sync before AR
NO
Live bus / dead line check before AR
NO
Dead bus / live line check before AR
NO
Dead bus / dead line check before AR
NO
Override of any check before AR
without consideration of CB
Operating mode with Man.Cl
closing time
2.0 V
Maximum voltage difference
0.10 Hz
Maximum frequency difference
10 °
Maximum angle difference
YES
Live bus / live line and Sync before MC
NO
Live bus / dead line check before
Man.Cl
NO
Dead bus / live line check before
Man.Cl
NO
Dead bus / dead line check before
Man.Cl
NO
Override of any check before Man.Cl
OFF
Operating mode Uph-e overvoltage
prot.
ON
Phase-Earth Overvoltage function is
85.0 V
Uph-e> Pickup
2.00 sec
T Uph-e> Time Delay
100.0 V
Uph-e>> Pickup
0.25 sec
Time of Carrier Send Impulse (Uph-e)
OFF
Operating mode 3U0 (or Ux) overvolt-
age
30.0 V
3U0> Pickup (or Ux>)
0.80
3U0 (or Ux) Reset ratio
2.00 sec
T (3U0 or Ux) Time Delay
0.25 sec
Time of Carrier Send Impulse (3U0 or
Ux)
Pickup
Start fault locator with
NO
Mutual coupling parall.line compensa-
tion
NO
Load Compensation
ON
Breaker Failure Protection is
Comments