Download Print this page
Siemens 7LF4 4210 Safety Notes
Siemens 7LF4 4210 Safety Notes

Siemens 7LF4 4210 Safety Notes

Advertisement

Quick Links

7LF4 4210
7LF4 4211
7LF4 4212
GB
Safety notes
This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installation, read
the operating instructions and observe the product-specific requirements for the installation location. Use only original spare parts for repair and
maintenance. Unauthorised opening and repair by other persons will invalidate all claims for liability, replacement or warranty services.
Function
Receptacle for
data key
+
1800W
1800W
1800W
Overview
Technical data
Supply voltage:
Effective power consumption: Approx. 1 W
Contact rating:
Parallel compensation:
Accuracy:
Terminal capacity:
Programmes :
Pulse start times:
Pulse duration:
Battery reserve:
Storage ambient:
Working ambient:
Overview of programmed
switching times for the week.
Resolution 0.5h
Switch status
Day, Time, Date
+
2300W
100W
100W
1800W
7LF4 4210
7LF4 4211
230V 50/60Hz
120V 50/60Hz
1 changeover contact 16A 250V~µ cos ϕ = 1
60VA max. 7µF
± 0,2 s / day under typical installation conditions
single strand
2
1,5...4 mm
56
84 (only if pulse function is activated)
1s ... 59min 59s
6 years
-20°C to +60°C
-20°C to +55°C
General information
• Start-up: after applying the supply voltage, the time switch
starts automatically with the last selected function. The relay
position is set by the current program.
• Battery backup
- Backlighting not active
- Data key READ/WRITE only via the menu.
MENU
OK
2300W
7LF4 4212
24V AC/DC ±10%
multi strand
2
1,5...2,5 mm
1/4
Select menu, back to main menu,
Hold down > 1s = operating display
Confirm selection or load parameters
Select menu options or set parameters
Set language
OK

Advertisement

loading

Summary of Contents for Siemens 7LF4 4210

  • Page 1 7LF4 4210 7LF4 4211 7LF4 4212 Safety notes This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installation, read the operating instructions and observe the product-specific requirements for the installation location. Use only original spare parts for repair and maintenance.
  • Page 2 Set time/date, summertime/wintertime and holiday period Summertime: ± 1 hour Europe: Factory set. SPECIAL: The switchover to/from summertime can be freely programmed by entering a start date and end date and is then executed each year on the same day of the week, e.g. Sunday.
  • Page 3 Contrast adjustment Data key Load the programs of the time switch on to a data key (WRITE KEY) Warning! all programs already existing on the data key will be overwritten. Load the programs from the data key to the time switch (READ KEY) Warning! all programs already programmed in the time switch will be overwritten.
  • Page 4 Activating the pulse function Pulses are also started during power failures. Aafter the power has been restored they are output for the remaining running time. Overlapping pulses restart the pulse start time. When switching from PASSIVE to ACTIVE, the program memory is cleared. Activating the pulse function Pulse duration 1s …...

This manual is also suitable for:

7lf4 42127lf4 4211