Aborting Test Patterns - Paradyne 3160-A4 Operator's Manual

Paradyne acculink dsu/csu data service unit models 3160-a4, 3161, 3164-a2, and 3165-a4 operator's guide
Table of Contents

Advertisement

8. Testing

Aborting Test Patterns

Use the Abort command to stop all test patterns or any selected test pattern active
on the DSU/CSU.
Procedure
To abort test patterns:
8-20
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk
Lpbk
F2
F1
3. From the Patterns screen, select Abort.
Patterns:
Abort
Send
F2
F1
4. From the Patterns Abort screen, press the desired Function key to abort either
All active test patterns, active Send test patterns, or the active Monitor (Mon)
test pattern.
Patterns: Abort
All
Send
F2
F1
If you select All, the DSU/CSU terminates all active test patterns and displays
the message Command Complete. Skip Step 5.
NOTE:
If you mistakenly choose to abort a test pattern that is not currently
running, a Command Complete message still displays and the test
pattern currently active still runs. Use the TStat branch to view the test
status to determine if the abort was successful.
March 2001
Ptrns
F3
Mon
F3
Mon
F3
3160-A2-GB24-10