C. Configuration Options
Table C-8. Alarm Configuration Options (4 of 4)
C-32
AlrmRelay: Disab
Next
Enab
Disab
Prev
Alarm Relay. Specifies whether an alarm condition for this circuit card activates the shared
alarm relay on the 3000 Series Carrier. The alarm deactivates if the condition(s) causing it
is corrected. An Alarm Cut-Off issued from the SDCP (or PC Emulation program) for a
particular carrier-mounted DSU/CSU also deactivates the alarm. The carrier-mounted
DSU/CSU does not reactivate the alarm relay until all alarm conditions for the unit are
cleared.
The following alarm conditions activate the alarm relay if this configuration option is
enabled:
T
Continuous Loss of Signal (LOS) or Out of Frame (OOF) at the network or DTE
Drop/Insert (DSX-1) interface.
T
Continuous Out of Frame (OOF) at any synchronous data port that has the Embedded
Data Link enabled.
T
Alarm Indication Signal (AIS) received at either the network or DTE Drop/Insert
(DSX-1) interface.
T
Yellow alarm signal received at either the network or DTE Drop/Insert (DSX-1)
interface.
T
Excessive Error Rate (EER) detected at the network interface.
T
An Excessive Error Rate (EER) detected at any synchronous data port that has the
Embedded Data Link enabled.
NOTE: This configuration option is available on carrier-mounted DSU/CSUs only.