G. IP Network Addressing Scenarios
Standalone at the Central Site
The first scenario
3160 DSU/CSU at the central site, with remotes connected via the FDL. In this
scenario, all 31xx Series devices are on the same subnet (135.18.1.0). The subnet
mask for each device is FF.FF.FF.00. A static route is set in the NMS host to
subnet 135.18.1.0.
135.18.1.2
135.18.1.3
135.18.1.4
135.18.1.5
Figure G-1.
G-2
(Figure G-1, Standalone at the Central
ETHERNET
NETWORK
10 BaseT PORT IP ADDRESS: 135.18.40.2
SUBNET 135.18.1.0
Standalone at the Central Site
March 2001
Site) shows a
135.18.40.1
SUBNET 135.18.40.0
135.18.1.1
135.18.1.1