Paradyne 3160-A4 Operator's Manual page 266

Paradyne acculink dsu/csu data service unit models 3160-a4, 3161, 3164-a2, and 3165-a4 operator's guide
Table of Contents

Advertisement

F. SNMP MIB Objects
Where these object identifiers are defined as follows:
T
T
T
T
T
T
T
T
T
Generic Interface Test Table – "ifExtnsTestResult" Object
(ifExtnsTestEntry 5)
This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.
T
T
T
T
Generic Interface Test Table – "ifExtnsTestCode" Object
(ifExtnsTestEntry 6)
This object contains a code that contains more specific information on the test
result. This object is defined as an object identifier. Only the following values are
supported by the DSU/CSU.
T
T
T
T
F-26
testLoopDTLB – OBJECT IDENTIFIER ::= [wellKnownTests 2]
testMonQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 3]
testMon511 – OBJECT IDENTIFIER ::= [wellKnownTests 4]
testSendQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 5]
testSend511 – OBJECT IDENTIFIER ::= [wellKnownTests 6]
testSendV54Up – OBJECT IDENTIFIER ::= [wellKnownTests 7]
testSendV54Down – OBJECT IDENTIFIER ::= [wellKnownTests 8]
testSendFT1Up – OBJECT IDENTIFIER ::= [wellKnownTests 9]
testSendFT1Down – OBJECT IDENTIFIER ::= [wellKnownTests 10]
none(1) – No test currently active.
inProgress(3) – A test is currently in progress.
notSupported(4) – The requested test is not supported.
unAbleToRun(5) – The requested test cannot run due to the state of the unit.
none – No further information is available. Used for the send pattern/code and
loopback tests.
inSyncNoBitErrors – A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has not detected any bit errors.
inSyncWithBitErrors – A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has detected bit errors.
notInSync – A monitor pattern (QRSS or 511) test has not synchronized on
the requested pattern.
March 2001
3160-A2-GB24-10

Advertisement

Table of Contents
loading

Table of Contents