Procedure
To clear the performance registers:
3160-A2-GB24-10
1. From the top-level menu screen, press the
appears on the screen.
2. Select Ctrl.
3. From the Control screen, press the
on the screen.
4. Select ClrReg.
Control:
Rel
LED
F1
F2
5. From the Clear Prf Regs screen, press F1 to clear the User registers.
Clear Prf Regs:
User
Prt1
F1
F2
If you selected User, the User performance registers are cleared, all
accumulators are reset to zero, and all status registers are cleared. The
current interval timer, the number of valid intervals count, and the total 24-hour
counts are reset to zero. The Command Complete message then appears.