Lamp Test; Aborting Test Patterns; Starting A Lamp Test - Paradyne 3163 User Manual

Paradyne acculink dsu/csu user's guide 3163
Hide thumbs Also See for 3163:
Table of Contents

Advertisement

Aborting Test Patterns

Use the Abort command to stop all test patterns or any
selected test pattern active on the DSU/CSU.
"
Procedure
To abort test patterns:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
Test:
Rlpbk Lpbk
F1
3. From the Patterns screen, select Abort.
Patterns:
Abort
F1
4. From the Patterns Abort screen, press the desired
Function key to abort either All active test
patterns, active Send test patterns, or the active
Monitor (Mon) test pattern.
Patterns: Abort
All
F1
If you select All, the DSU/CSU terminates all
active test patterns and displays the message
Command Complete. Skip Step 5.
3163-A2-GB20-10
Ptrns
F3
F2
Send
Mon
F2
F3
Send
Mon
F2
F3
If you mistakenly choose to abort a
test pattern that is not currently
running, a Command Complete
message still displays and the test
pattern currently active still runs. Use
the TStat branch to view the test
status to determine if the abort was
successful.
5. From the Abort screen, press the Function key that
corresponds to the network or port for which you
want to abort a test pattern. Use the scroll keys, if
necessary.
The DSU/CSU terminates the selected test pattern
and displays the message Command Complete.

Lamp Test

Use the Lamp Test commands to start and stop a test of
the DSU/CSU front panel LCD and LEDs.

Starting a Lamp Test

"
Procedure
To start a Lamp test:
1. From the top-level menu screen, select Test.
2. From the Test screen, press the
Lamp selection appears on the screen.
3. From the Test screen, select Lamp.
March 1999
Monitoring and Testing
NOTE
Abort: Send or Mon
NET
Prt1
F1
F2
F3
key until the
4-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acculink 3163 dsuAcculink 3163 csu

Table of Contents