Paradyne 3160-A4 Operator's Manual page 186

Paradyne acculink dsu/csu data service unit models 3160-a4, 3161, 3164-a2, and 3165-a4 operator's guide
Table of Contents

Advertisement

C. Configuration Options
Table C-7. User Interface Configuration Options (3 of 11)
C-20
ComConnPrefix:
Next
Edit
Clear
Prev
Carrier Communication Port Connect Prefix. Specifies the connect prefix to the dial
directory phone number. When you make a connection or the DSU/CSU automatically
makes a connection (dial-out alarms or traps) through the communication port, the
connect prefix and the dial directory phone number are used to establish the connection.
The connect prefix is an ASCII text string and may be up to 20 characters in length. If the
connect prefix is NULL, then no connect prefix is used.
Edit – Allows you to edit and/or display the connect prefix using the generic text string
entry screen.
Clear – Allows you to clear the connect prefix. The connect prefix is set to a null string.
NOTES:
– This configuration option is available on carrier-mounted DSU/CSUs only.
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
– If ComExtDev is configured for Other and the external device requires characters
after the dial phone number, you must append the characters to the phone number.
ComConnected:
Next
Edit
Clear
Prev
Carrier Communication Port Connect Indication String. Specifies the communication
port's connect indication string. When you make a connection or the DSU/CSU
automatically makes a connection (dial-out alarms or traps) through the communication
port, this string determines that the connection has been established. The connect
indication string is an ASCII text string and may be up to 20 characters in length. If the
connect indication string is not received within 1 minute, it will time-out the connection. If
the connect indication string is NULL, the communication port's receive data stream is not
searched and a transition in the Carrier Detect (CD) lead is used to determine that a
connection has been established.
Edit – Allows you to edit and/or display the case-sensitive connect indication string using
the generic text string entry screen.
Clear – Allows you to clear the connect indication string. The connect indication string is
set to a null string.
NOTES:
– This configuration option is available on carrier-mounted DSU/CSUs only.
– This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
March 2001
3160-A2-GB24-10

Advertisement

Table of Contents
loading

Table of Contents