Table C-6. General Configuration Options (2 of 2)
3160-A2-GB24-10
Clock Rate: 1544
Next
2048
1544
8
External Clock Rate. Specifies the clock rate when the master clock source is configured
for external clock (Ext). This configuration option does not appear when the clock source
is not an external clock.
2048 – Sets the input rate of the external clock to 2,048 kHz.
1544 – Sets the input rate of the external clock to 1,544 kHz.
8 – Sets the input rate of the external clock to 8 kHz.
NOTES:
– This configuration option is only available on 2-port and 4-port DSU/CSUs.
– External clock rate 2,048 kHz does not imply E1 compatibility.
Tst Timeout: Enab
Next
Enab
Disab
Prev
Test Timeout. Specifies whether user-initiated loopback and pattern tests have durations
that are specified by the Tst Duration configuration option.
Enab – Loopback and pattern tests initiated on the DSU/CSU have specified durations.
Disab – Disables test timeout. The tests are terminated manually.
NOTE: For DSU/CSUs that are remotely managed through an inband data stream
such as EDL or FDL, the recommended setting is Enab. If tests are inadvertently left in
the active state, the Enab setting will allow the test to timeout (terminate) after a
specified time.
Tst Duration: 10
Next
Up
Down
Save
Test Duration. Specifies the duration (1 to 120 minutes) of user-initiated loopback and
pattern tests. (The Tst Timeout configuration option must be set to Enab.) Use the left or
right arrow key to position the cursor on the digit you want to change. Use the Function
keys (Up or Down) to increment or decrement the digit.
Up – Increments the test duration.
Down – Decrements the test duration.
Save – Stores the test duration.
March 2001
Prev
Prev
C. Configuration Options
C-17