Paradyne 3160-A4 Operator's Manual page 124

Paradyne acculink dsu/csu data service unit models 3160-a4, 3161, 3164-a2, and 3165-a4 operator's guide
Table of Contents

Advertisement

7. Monitoring and Troubleshooting
Device Health and Status Messages
Use the Device Health and Status branch to view the current health and status
messages for the DSU/CSU.
these messages in priority order.
Procedure
To display device health and status:
7-4
1. From the top-level menu screen, select Stat.
2. From the Status screen, select DevHS.
Status:
DevHS
STest
F1
F2
Alarm/status messages appear on Line 2 of the LCD in priority order (highest
to lowest). The DSU/CSU is polled for current status every ten seconds. If the
status has changed from the last poll, the Health and Status screen is updated
and the highest priority message is displayed.
3. Use the scroll keys, if necessary, to scroll additional device health and status
messages onto the LCD.
Device H/S:
OOF at DTE
F2
F1
The Auto Device Health and Status screen appears when there is no activity
(no keys pressed) on the active physical interface for five minutes. Only the
highest priority message appears on Line 2 of the LCD.
Auto Dev H/S
OOF at DTE
F1
F2
March 2001
Table 7-2, Device Health and Status
Perf
F3
F3
F3
Messages, lists
3160-A2-GB24-10

Advertisement

Table of Contents
loading