Technical Specifications - Paradyne 3160-A4 Operator's Manual

Paradyne acculink dsu/csu data service unit models 3160-a4, 3161, 3164-a2, and 3165-a4 operator's guide
Table of Contents

Advertisement

Technical Specifications

Overview
The technical specifications for the standalone DSU/CSUs are listed in
Models 3160/3164/3165 DSU/CSU's Technical
specifications for the carrier-mounted DSU/CSUs are listed in the
3151 CSU and 3161 DSU/CSU General Information Guide
Table B-1.
3160-A2-GB24-10
Models 3160/3164/3165 DSU/CSU's Technical Specifications (1 of 2)
Specifications
POWER REQUIREMENTS
Standard:
AC Power Module
Optional dc (3164 only):
+24 Vdc
–48 Vdc
–48 Vdc Redundant
POWER CONSUMPTION
AND DISSIPATION
3160
3164
3165
ENVIRONMENT
Operating Temperature
Storage Temperature
Relative Humidity Shock and
Vibration
March 2001
Specifications. The technical
Criteria
Refer to the labeling on the ac power module for input
requirements
+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to –60 Vdc, 0.25A
–38 Vdc to –60 Vdc, 0.25A
8.4 watts, 28.7 Btu per hour at 115 Vac, 60 Hz
(includes external transformer)
12.0 watts, 41 Btu per hour at +24 and –48 Vdc
16.0 watts, 55.0 Btu per hour at 115 Vac, 60 Hz (includes
external transformer)
7.5 watts, 25.6 Btu per hour at 115 Vac, 60 Hz
(includes external transformer)
6.6 watts, 22.5 Btu per hour at 100 Vac, 50 Hz
(includes external transformer)
32 F to 122 F (0 C to 50 C)
–4 F to 158 F (–20 C to 70 C)
5%—95% (noncondensing)
Withstands normal shipping and handling
B
Table B-1,
ACCULINK
.
B-1

Advertisement

Table of Contents
loading

Table of Contents