Operation
Specifying the Community Name(s) and Access Type(s)
"
3-24
5. Select Mgmt.
Edit:
User
Alarm Mgmt
F1
6. From the Mgmt Config screen, select Gen.
Mgmt Config:
Gen
Trap
F1
7. Press F1 (Next) until the Com Link configuration option appears.
8. Press F2 (PPP) or F3 (SLIP).
Com Link:
Next
PPP
F1
You have the capability of specifying up to two community names (community
name 1 and community name 2) to be used by external SNMP managers when
trying to access objects in the DSU/CSU's MIB. Once you specify the community
name(s), you must then specify the type of access to the MIB that SNMP
managers in the community are permitted to have.
Procedure
To specify the community name 1 and its access type:
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the
the screen.
March 1999
F2
F3
F2
F3
SLIP
F3
F2
key until the Mgmt selection appears on
3160-A2-GB21-80