Power Input Connector

The input power connector leads are shown in Table D-11. Pin 1 is at the lower
right of the connector and Pin 6 at the upper left as you face the back of the unit.
Optional DC Power Cable
The dc power cable (Figure D-11) is a 14.5-foot, 18 AWG stranded cable. The
connector is terminated at one end with a 6-position connector. The other end of
the cable is terminated with a bare wire that should be connected to a dc power
source.
single source of +24 Vdc or up to two sources of – 48 Vdc (A and B). You cannot
connect +24 Vdc and – 48 Vdc to the same unit. See the installation instructions
in Chapter 2,
Figure D-11. DC Power Cable
3160-A2-GB21-80
Table D-11. DC Power Connector
Signal
Pin Number
– 48 Vdc Return
1, 2
– 48 Vdc A
6
– 48 Vdc B
5
+24 Vdc
5
+24 Vdc Return
4
Chassis Ground
3
Figure D-11
shows the wire colors. The power source can be either a
Installation
.
March 1999
Pin Assignments
6
5
4
3
2
1
99-16291
D-15