Maintenance

Starting a Payload Loopback

"
4-24
The Payload Loopback command (PLB) loops the received signal on the network
interface back to the network. The signal is looped back as close to the DTE
Drop/Insert (DSX-1) port as possible (after it has passed through the framing
circuitry of the DSU/CSU). Framing CRCs and BPVs are corrected.
DSU
DTE
ALL
(DSX-1)
1s
ALL 1s
ALL 1s
PORT 2
PORT 1
Procedure
To perform a Payload loopback:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
Test:
Rlpbk Lpbk
F1
3. From the Loopback screen, select PLB.
Loopback:
Abort
LLB
F1
Test Started appears on Line 2. If a Payload loopback is already in
progress, the Already Active message appears. If an invalid combination
of loopbacks is in progress, the error message Invld Test Combo appears
(see
Table 4-8
for valid loopback test combinations).