Paradyne 3160 Operator's Manual page 115

Paradyne acculink dsu/csu models 3160-a2, 3161-b3, 3164-a2, and 3165-a2 operator's guide
Hide thumbs Also See for 3160:
Table of Contents

Advertisement

3160-A2-GB21-80
Table 4-4. Enterprise-Specific Trap Definitions
Trap Value
enterpriseClockFail(1)
enterpriseSelfTestFail(2)
enterpriseDeviceFail(3)
enterpriseTestStart(5)
enterpriseConfigChange(6)
enterpriseTestClear(105)
Table 4-5. SNMP Trap per Interface
Interface
T1 Network
DTE Drop/Insert (DSX-1)
Synchronous Data Ports
March 1999
Event
The currently configured master clock source has failed.
A DSU/CSU hardware failure is detected at self-test. This
trap is generated after DSU/CSU initialization.
An internal DSU/CSU failure is detected by the operating
software.
A test is initiated.
A configuration option is changed.
A test is concluded.
Trap Meaning
Up = No alarm or test conditions.
Down = Alarm or test conditions.
Up = No alarm or test conditions, and the interface is
enabled.
Down = Alarm or test conditions, or the interface is
disabled.
Up = No test conditions, the port is assigned to a network
interface, and both CTS and DSR are ON.
Down = Test conditions, the port is unassigned, or either
CTS or DSR is off.
Maintenance
4-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents