Establishing Access Security On A Port - Paradyne 3160 Operator's Manual

Paradyne acculink dsu/csu models 3160-a2, 3161-b3, 3164-a2, and 3165-a2 operator's guide
Hide thumbs Also See for 3160:
Table of Contents

Advertisement

Operation

Establishing Access Security on a Port

"
3-48
5. Select Gen.
Edit:
NET
Chan
F1
6. Press F1 (Next) to display the next configuration option (Clock Src).
7. Select the master clock source. For external, press the
selection appears on the screen.
8. Select Ext (external timing).
Clock Src:Ext
Prt1
F1
9. Select the appropriate external clock rate by pressing the corresponding
Function key. This step is mandatory if you have chosen external clocking.
Clock Rate:1544
Next
2048
F1
Although the password feature is available, it is not required as a factory default.
If used, it ensures access security before device control is passed to a device
connected to a port. The password configuration option can be individually set for
the COM or MODEM port, or both if security is needed on both port types. The
default is None. The password itself is set separately (refer to the following
section,
Setting a Password
Procedure
To establish access security on a port:
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
March 1999
Gen
F2
F3
Int
Ext
F2
F3
1544
F3
F2
).
key until the Ext
3160-A2-GB21-80