Technical Specifications - Paradyne 3160 Operator's Manual

Paradyne acculink dsu/csu models 3160-a2, 3161-b3, 3164-a2, and 3165-a2 operator's guide
Hide thumbs Also See for 3160:
Table of Contents

Advertisement

Technical Specifications

Overview
3160-A2-GB21-80
The technical specifications for the standalone DSU/CSUs are listed in Table B-1.
The technical specifications for the carrier-mounted DSU/CSUs are listed in the
ACCULINK 3151 CSU and 3161 DSU/CSU General Information Guide .
Table B-1. Models 3160/3164/3165/DSU/CSU's Technical Specifications (1 of 2)
Specifications
POWER REQUIREMENTS
Typical:
AC Power Module
Optional:
+24 Vdc
– 48 Vdc
– 48 Vdc Redundant
POWER CONSUMPTION
AND DISSIPATION
ENVIRONMENT
Operating Temperature
Storage Temperature
Relative Humidity Shock and
Vibration
March 1999
Criteria
Refer to the labeling on the ac power module for input
requirements
+20 Vdc to +32 Vdc, 0.50A
–38 Vdc to – 60 Vdc, 0.25A
–38 Vdc to – 60 Vdc, 0.25A
3160:
6.5 watts, 22.1 Btu per hour at +24 Vdc;
6.2 watts, 21.3 Btu per hour at – 48 Vdc
8.7 watts, 29.7 Btu per hour at 100 Vac (includes
external transformer)
9.2 watts, 31.4 Btu per hour at 120 Vac (includes
external transformer)
3164, 3165:
12.0 watts, 41 Btu per hour at +24 and – 48 Vdc
16.0 watts, 55.0 Btu per hour at 115 Vac (includes
external transformer)
32 F to 122 F (0 C to 50 C)
– 4 F to 158 F (–20 C to 70 C)
5%—95% (noncondensing)
Withstands normal shipping and handling
B
B-1