Paradyne 3160 Operator's Manual page 250

Paradyne acculink dsu/csu models 3160-a2, 3161-b3, 3164-a2, and 3165-a2 operator's guide
Hide thumbs Also See for 3160:
Table of Contents

Advertisement

IP Network Addressing Scenarios
Scenario 5
LAN
ADAPTER
ETHERNET
SUBNET 135.140.22.0
F-6
Figure F-5 illustrates multiple COM ports on the same carrier connected to
different NMSs. This might be used in service-provider applications, where some
of the carrier's circuit cards (and their remotes) are managed by one NMS and
other cards are managed by a different NMS. In this example, each card and
remote is on a separate subnet. Also, note that each LAN Adapter connection is
on a different subnet. The subnet mask is FF.FF.FF.00. The NMS hosts would
only need routes added for the subnets that they are to manage.
SUBNET 135.18.23.0
135.18.23.2
COM IP
ADDRESS:
135.140.22.95
135.140.22.79
Figure F-5. Multiple COM Ports Connected to Different NMSs
March 1999
SUBNET 135.18.34.0
T1
T1
135.18.34.2
C O
M S
P H
E R
E
3 0
0 0
COM IP
ADDRESS:
135.18.40.5
LAN
ADAPTER
135.18.40.1
ETHERNET
SUBNET 135.18.40.0
496-14649-02
3160-A2-GB21-80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents