Maintenance
"
4-8
Procedure
To clear the performance registers:
1. From the top-level menu screen, press the
appears on the screen.
2. Select Ctrl.
3. From the Control screen, press the
appears on the screen.
4. Select ClrReg.
Control:
Rel
LED
F1
5. From the Clear Prf Regs screen, press F1 to clear the User registers.
Clear Prf Regs:
User
Prt1
F1
If you selected User, the User performance registers are cleared, all
accumulators are reset to zero, and all status registers are cleared. The
current interval timer, the number of valid intervals count, and the total
24-hour counts are reset to zero. The Command Complete message then
appears.
Table 4-3. Performance Registers (1 of 3)
Register
Interval Description
Event
ESF error events counter. An error
event is an ESF frame with either a
Cyclic Redundancy Check (CRC)
error or an Out Of Frame (OOF)
event. The maximum count is
65,535. This register is only reset
as a result of a reset command
from the network. This register is
valid for the current interval only.
CurTimer
Current interval timer. This register
records the number of seconds in
the current 15-minute interval. The
maximum is 900 seconds. This
register is valid for the current
interval only.
March 1999
key until the ClrReg selection
ClrReg
F2
F3
Prt2
F2
F3
Totals Description
N/A
N/A
key until the Ctrl selection
3160-A2-GB21-80