Hide thumbs Also See for ACCULINK 3165 DSU:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
ACCULINK 3165 DSU/CSU
QUICK REFERENCE
Document No. 3165-A2-GL11-40

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne ACCULINK 3165 DSU

  • Page 1 All manuals and user guides at all-guides.com ACCULINK 3165 DSU/CSU QUICK REFERENCE Document No. 3165-A2-GL11-40...
  • Page 2 Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
  • Page 3: Quick Reference

    It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Service & Support Technical Manuals T1/E1 Digital Access Devices.
  • Page 4: Quick Start Procedure

    All manuals and user guides at all-guides.com Quick Start Procedure The following procedure is for experienced DSU/CSU users who are familiar with the 3165 DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 316x Data Service Unit/Channel Service Unit Operator’s Guide for more information.
  • Page 5 All manuals and user guides at all-guides.com PSTN Modem Modem Terminal SNMP Manager Workstation Front Modem Modem Panel 3165 DSU/CSU Network Port Port Port Port 3165 DSU/CSU COM PORT MODEM NETWORK POWER AUX PORT Network CLASS 2 CAUTION: AUX PORT OR COM PORT MUST NOT BE CONNECTED TO PSTN OR T1 NETWORK INPUT Port T1 Network...
  • Page 6: Configuration Options

    All manuals and user guides at all-guides.com Configuration Options Configuration options are accessed from the Configuration branch of the front panel menu. DSU ESF Stat Test Cnfig Ctrl...
  • Page 7 All manuals and user guides at all-guides.com Factory default configuration options are shown in boldface type in the following tables. Table 1. Port Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description E530 E530 V.35 V.35 Selects the port type: EIA-530A, Selects the port type: EIA-530A, Port Type: Port Type:...
  • Page 8 All manuals and user guides at all-guides.com Table 1. Port Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description 10E–4 10E–4 10E–5 10E–5 10E–6 10E–6 Err Rate: Selects the error rate threshold for (Excessive Error (Excessive Error Excessive Error Rate Alarm Excessive Error Rate Alarm.
  • Page 9 All manuals and user guides at all-guides.com Table 3. Channel Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Block Block Determines how channels are Determines how channels are ACAMI ACAMI Assign By: Assign By: assigned: contiguous blocks, assigned: contiguous blocks, ACAMI ACAMI or individual channels.
  • Page 10 All manuals and user guides at all-guides.com Table 3. Channel Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Clears (unassigns) channels for Clear Clear this port. N1 (D1) N1 (D1) N2 (D2) N2 (D2) N3 (D3) N3 (D3) N4 (D4) N4 (D4) N5 (D5)
  • Page 11 All manuals and user guides at all-guides.com Table 4. General Configuration Options Option Factory 1 Factory 2 Comments/Description Enab Enab Gen Yellow: Gen Yellow: Yellow alarm is generated by the Yellow alarm is generated by the (Generate Yellow) DSU/CSU on LOS, LOF, or AIS. Disab Disab Selects the clock source to be...
  • Page 12 All manuals and user guides at all-guides.com Table 5. User Configuration Options (1 of 3) Option Factory 1 Factory 2 Comments/Description Enab Enab Allows bypass of self-test on Allows bypass of self-test on Self-Test: Self-Test: initialization. Disab Disab Enab Enab Controls whether front panel Controls whether front panel FP Access:...
  • Page 13 All manuals and user guides at all-guides.com Table 5. User Configuration Options (2 of 3) Option Factory 1 Factory 2 Comments/Description CStop Bits: CStop Bits: Selects the number of stop bits for (Communication Port (Communication Port the COM port. the COM port. Stop Bits) Bit ) Specifies whether the COM port...
  • Page 14 All manuals and user guides at all-guides.com Table 5. User Configuration Options (3 of 3) Option Factory 1 Factory 2 Comments/Description MoDiscTm: Specifies the period of inactivity Specifies the period of inactivity (Modem Port (Modem Port (1 t 60 i (1 to 60 minutes) that causes a t ) th t Disconnect Time)
  • Page 15 All manuals and user guides at all-guides.com Table 6. Alarm Configuration Options Option Factory 1 Factory 2 Comments/Description Disab Disab Does not display alarm messages. Sends alarm messages to Modem Modem Modem port. Alrm Msg: Sends alarm messages to COM port.
  • Page 16 All manuals and user guides at all-guides.com Table 7. Management – General Configuration Options (1 of 2) Option Factory 1 Factory 2 Comments/Description Disab Disab Specifies whether the DSU/CSU SNMP Mgt: SNMP Mgt: responds to SNMP session responds to SNMP session Enab Enab requests.
  • Page 17 All manuals and user guides at all-guides.com Table 7. Management – General Configuration Options (2 of 2) Option Factory 1 Factory 2 Comments/Description Edit Edit The Subnet Mask needed to Com NetMask: Com NetMask: access the device when the COM access the device when the COM Clear Clear...
  • Page 18 All manuals and user guides at all-guides.com Table 8. Management – Trap Configuration Options Option Factory 1 Factory 2 Comments/Description The number of trap managers Num Trap Mgrs: 2–6 2–6 supported by the device. Specifies the IP address for each Edit Edit trap manager.
  • Page 19: Important Safety Instructions

    All manuals and user guides at all-guides.com Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be used with a 3-wire grounding type plug – a plug which has a grounding pin.
  • Page 20: Emi Warnings

    The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation. WARNING: To Users of Digital Apparatus in Canada: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
  • Page 21 All manuals and user guides at all-guides.com Notice to Users of the United States Telephone Network 1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label that contains, among other information, the FCC registration number for this equipment.
  • Page 22 — Via the Internet: Visit the Paradyne World Wide Web site at http://www.paradyne.com — Via Telephone: Call our automated call system to receive current information via fax or to speak with a company representative.
  • Page 23 All manuals and user guides at all-guides.com The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.