Alarm Configuration Options
3160-A2-GB21-80
Table C-7. User Interface Configuration Options (10 of 10)
TnInActTm: Disab
Next
Enab
Disab
Prev
Telnet Inactivity Timeout. Specifies whether the Telnet session disconnects after a
period of inactivity specified by the TnDiscTm configuration option.
Enab – The Telnet session disconnects after the period of inactivity specified by the
TnDiscTm configuration option.
Disab – The Telnet session does not disconnect due to inactivity.
TnDiscTm: 5
Next
Up
Down
Save
Telnet Disconnect Time. Specifies the period of time (1 to 60 minutes) before the Telnet
session disconnects due to inactivity. (The TnInActTm configuration option must be set
to Enab.) Use the left or right arrow key to position the cursor on the digit you want to
change. Use the Function keys (Up or Down) to increment or decrement the digit.
Up – Increments the time delay.
Down – Decrements the time delay.
Save – Stores the time delay for use with inactivity disconnects.
NOTE:
A triangular symbol (Y) identifies a configuration option that is available on
carrier-mounted DSU/CSUs only.
Table C-8. Alarm Configuration Options (1 of 4)
Alrm Msg: Disab
Next
Disab
Modem
Alarm Messages. Controls the generation of alarm messages, which are routed to an
ASCII terminal or printer attached to the communication port and/or the modem port.
Disab – Prevents an alarm message for any alarm conditions.
Modem – Enables alarm messages routed to the modem port. This selection does not
appear on carrier-mounted DSU/CSUs.
Com – Enables alarm messages routed to the communication port.
Both – Enables alarm messages routed to both the modem and communication ports.
This selection does not appear on carrier-mounted DSU/CSUs.
NOTE:
Alarm messages are only sent to the communication port if the Com Use
configuration option is set to ASCII, otherwise the alarm messages are
discarded.