Performance Reports

3160-A2-GB21-80
Table 4-2. Device Health and Status Messages (2 of 2)
Message
Description
Test in progress
A test is currently active. Select Tstat (in the Stat branch) to display
more test information.
Modem
The integral modem is currently connected. This message is only
Connected
displayed for standalone DSU/CSUs.
Master Clk fail
The master clock has failed. Timing for the DSU/CSU is provided
by the internal clock.
DSU Operational
This message only appears if there are no valid alarm or status
messages.
When the network interface is configured for ESF operation, network
performance is continuously monitored and maintained in two sets of aggregate
registers: Carrier Network Interface Registers (Telco) and User Network Interface
Registers (User). The User registers contain an extra status register (Status
Event). Registers shown on the front panel LCD are listed in
registers are status registers that collect performance data for the previous
24-hour period. Performance data is updated in 15-minute intervals. After
15 minutes, the current interval is rolled over into a set of accumulator registers
that represent the previous 96 15-minute intervals for the register. An interval
total of how many of the 96 registers contain valid data is also kept, as well as a
24-hour total for each accumulator register.
For 2-port and 4-port DSU/CSUs, port performance is continuously monitored
and maintained in memory registers when the port is configured to use EDL. The
DSU/CSU maintains two sets of port registers for each synchronous data port:
far-end port registers and near-end port registers. These registers are status
registers that collect performance data for the previous 8-hour period. Port data is
updated in 15-minute intervals. After 15 minutes, the current interval is rolled over
into a set of accumulator registers that represent the previous 32 15-minute
intervals for the register. An interval total of how many of the 32 registers contain
valid data is also kept, as well as a 8-hour total for each accumulator register.
NOTE:
The following procedure is an example only. Screen displays may vary
depending on the model and configuration of the DSU/CSU. The
procedures for displaying Telco and port registers are similar to this example.
March 1999
Maintenance
Table
4-3. These
4-5