REPORTING FORMAT
ADEMCO/SILENT KNIGHT - Slow 10 baud
ADEMCO/SILENT KNIGHT - Fast 20 baud
FRANKLIN/SESCOA/DCI/VERTEX - Fast 20 baud
Table 4 Digital Communicator Reporting Formats
+
If you associate an Action with a Digital Communicator
Number which transmits in CONTACT ID, TELIM,
CESA or SIA Reporting Format, any other Digital
Communicator Numbers, assigned to the Action
concerned, must transmit in the same Reporting For-
mat.
All If this option is Enabled, the Control Panel will call
all the numbers when the corresponding Action occurs.
If this option is Disabled (at default), the Control Panel
will terminate the call cycle after the first successful call.
To enable (Y) this option, press ENTER or double click
on the respective cell.
Description This editable field is for the Action label.
Events This button will allow you to select the Events
that will trigger the Action.
CONTACT ID If the selected telephone number is asso-
ciated with CONTACT ID, it is possible to associate this re-
porting format automatically to priority events, by selecting
and confirming CONTACT ID (see the Figure 38).
DEFAULT SIA If the selected telephone num-
ber is associated with SIA, it is possible to associ-
ate this reporting format automatically to priority
events, by selecting and confirming SIA (see the
Figure 38).

Voice Messages

This function is provided by the K3/VOX2 Voice
Board (accessory item). The K3/VOX2 will allow
the Control Panel to manage up to 64 Voice
Messages with programmable quality and
length. The amount of message time available
depends on the sound quality of the messages,
and ranges from 3 minutes 48 seconds for high
sound quality, to 8 minutes 44 seconds for low
sound quality (refer to "K3/VOX2 Voice board" in
the "APPENDIX").
52
RADIONICS - 40 baud
SCANTRONIC - 10 baud
CONTACT ID
TELEMAX
TELIM
CESA
SIA
SIA over B-NET
CUSTOMER CODE
TYPE
digits (validity)
Pulse
Pulse
Pulse
3/4 (0 ÷ F)
Pulse
Pulse
DTMF
4 (0 ÷ F)
Pulse
3 (0 ÷ 9)
Pulse
6 (0 ÷ 9)
FSK
5 (0 ÷ 9)
LAN
4 (0 ÷ 9)
+
Message No. 63 can be used for the Memo func-
tion (refer to "Memo" in the USER'S MANUAL) and
Message No. 64 for the Continuous Recording
function (refer to "Enable Continuous Recording"
under "Options"). If the Home Memo and/or Contin-
uous Recording facilities are not used, these mes-
sages can be used for other purposes.
The Voice messages can be used for the:
Ø Zone status control
Ø Answering Machine message
Ø Dialler messages
Ø Memo function
Ø Continuous Recording function
+
Voice Messages can be recorded and played at
the Keypad, as described in the KEYPAD
PROGRAMMING MANUAL.
The layout of the Voice Messages page is as follows.
No. This is the non-editable Message ID Number. This
number substitutes the Message Description in some
parts of the application.
Figure 38 Digital Communicator Actions window
EVENT CODE
NOTES
digits (validity)
½ (0 ÷ F)
See Event-Actions
Page
1 (0 ÷ 9)
Pre-set
2 (0 ÷ 9)
See Event-Actions
Page
0 = A
0 = A