Ø Arm Partitions
Ø Disarm Partitions
Ø Arm in A and B Mode
Ø Stop Partition Alarms
+
Commands will affect ONLY the Partitions com-
mon to both the Reader and Key/Card in use.
For example, if you attempt to Arm the system at a Reader
that is enabled on Partitions no. 1 and no. 2, with a
Key/Card that is enabled on Partitions no. 1 and no. 3,
ONLY Partition no. 1 will Arm (Partition no. 1 is common to
both the Reader and Key/Card). The Readers page will al-
low you to set up the Readers, as follows.
+
For information regarding the ü, No. and Descrip -
tion parameters, refer to the "Configuration" section.
M This attribute will enable the Reader for Monitoring
purposes (i.e. To signal specific events — to be pro -
grammed by the Installer).
+
Monitoring Readers (Readers with the M attrib -
ute) CANNOT be used for system control purposes
but will be able to generate Valid Key, Key at
Reader events and Valid Key on Partition.
The Expand button at the bottom of the page will open
the Readers table.
If you are programming System Control Readers: select
the Reader Partitions, and set up the A and B Mode
Arming configurations (refer to the following paragraphs).
If you are programming Monitoring Readers: select the
Events to be monitored (refer to the following paragraphs).
RED spot This row will allow you to assign (ü) the
Reader to the Partitions (01 through 32).
To view the Partition Description: click the Descrip-
tion button (bottom of page) then position the cursor on
the Partition check box.
To highlight a Reader: hold down the SHIFT key and
click anywhere on the Reader table, then release the
SHIFT key.
To highlight a group of Readers: hold down the SHIFT
key and click anywhere on the tables of the first and last
Readers of the group, then release the SHIFT key.
To assign the Reader Partitions (quick mode): highlight
the Reader concerned, click the Partitions button then
select:
None — to Disable the highlighted Readers on all Par-
titions;
All — to Enable the highlighted Readers on all Partitions;
Toggle — to invert the current status of the highlighted
Readers.
To Copy data (Enabled Partitions, A and B Mode Arm-
ing configuration): highlight the Reader to be copied;
right click the mouse; select Copy from the pop-up
menu; highlight the Readers to be pasted; right click the
mouse, then select Paste from the pop-up menu.
KYO320
YELLOW spot This programming section will allow
you to set up the A Mode Arming configuration. If an A
Mode Arming request is made at a Reader, the Parti -
tions will Arm/Disarm in accordance with the pro -
grammed configuration, as follows:
Ø D — the corresponding Partition will Disarm
Ø N — the status of the corresponding Partition will re -
main unchanged (None)
Ø A — the corresponding Partition will Arm
Ø S — the corresponding Partition will Arm in Stay
mode (i.e. Zones with the Internal Attribute will be
Bypassed).
Ø I — the corresponding Partition will Arm in Instant
Mode (Stay with zero Entry Delay)
GREEN spot As per the YELLOW spot but for B
Mode.
Display Panel Alarm in Memory
abled (Default setting), the RED LED will signal the pres -
ence of Panel Alarm memory.
Display Partition Alarm in Memory
enabled (Default setting), the RED LED will signal the
presence of Alarms and/or Tamper memory relative to the
Keypad partitions.
+
Monitoring Readers (Readers with the M attribute)
CANNOT be used for system control purposes.
Event no. This programming section will allow you to
set up the Monitoring Readers events will be able to
signal. Enter the Identifier Number of the Event that is to
be signalled on the LED, or double-click and select the
Event from the Events list, then click OK.
+
The Event no. section is for Monitoring Readers
ONLY (Readers with "M" attribute)
n Power station
The Power stations page will allow you to setup the
system Power Stations.
+
For information regarding the ü, No. andDescription
parameters, refer to the "Configuration" section.
Mains fault warning delay This programming field
will allow you to set the Mains fault warning delay (in
seconds). Interruption of the Mains power supply to the
Power station will trigger the programmed delay. If
power is not restored before the delay expires, the Con -
trol Panel will signal Mains fault.
Low battery delay This programming field will allow
you to set the Low battery delay (in seconds). If the
Power station battery voltage drops below 11.4 V, the
Control Panel will trigger the programmed delay. If the
Voltage is not restored before the delay expires, the
Control Panel will signal Low battery.
PROGRAMMING
If this option is en -
If this option is
33