Voice Messages; And Mode Zones; Vectorrx Wireless Receivers - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

If you select Step 500 ms, you will be able to set a Pulse
length of 0.5 through 32 seconds in 0.5 second steps.
If you select Step 30 sec., you will be able to set a
Pulse length of 30 through 1920 seconds (32 minutes)
in 30 second steps.
+
If you select the Step 30 sec. option, the Control
panel will round off the Pulse length to the nearest
5 seconds. For example, if you set 30 seconds, the
Control panel will trigger an Alarm when it detects a
Pulse between 25 and 30 seconds.
n Voice Messages
This feature is provided by the K3/VOX2 kit (optional
Voice Board + Speaker). If this optional feature is avail-
able, you will be able to assign two voice messages to
the Zone. These messages will allow the User to make
status enquiries (with voice answer) over the phone.
The Voice Messages can be recorded, played and de-
leted at the Keypad (refer to "Voice Messages").
Standby This field will allow you to select the Message
which will be played when the Zone is in Standby status.
+
If no message is selected, Standby status will be
signalled by a Beep.
Alarm This field will allow you to select the Message
which will be played when the Zone is in Alarm, Tamper
or Short Circuit status.
+
If no Voice Message is selected, Zone Alarm will
be signalled by two Beeps.
Default Code In Contact ID and SIA protocols case,
the associated code changes with Alarm Types (See
Alarm Zones). In this way, a Fire Zone (for example) will
be associated to a particular code that will be different
from a Duress Zone or 24h Zone.

AND Mode Zones

This option will allow you to set up the system to
generate Alarms when violation occurs on a
specific group of Zones within a set time.
No. This field shows the Identifier number of
the AND Zone group.
Window This field will allow you to set the time
within which ALL the Zones of the respective
group must detect violation.
The And Zones page will allow you to set up to
32 Groups, each with:
Ø up to 8 Zones
Ø a set time (Window) within which ALL the
Zones in the respective Group must detect
violation.
From Standby status, each Group will operate
as follows: violation of any of the Zones in the
Group will not generate an Alarm but will start
KYO320
the programmed Window.
If ALL the Zones in a specific Group detect violation
within the programmed window, the system will gener -
ate the respective Zone Alarms, and will indicate the
Zones concerned on the Keypad.
If NOT ALL the Zones in the Group detect violation
within the programmed Window, the system will refresh
the window and restore to Standby.
After generating a Zone Group Alarm, the system will
be unable to generate further Alarm cycles until ALL the
AND Zones concerned restore to Standby.
'Reset Partition Alarm', 'Arm/Disarm Partition' or 'Stop
Partition Alarm' operations will restore ALL the AND
Zones of the Partition concerned to standby.
The Zones of a Group need not have Partitions in common.
AND Zones can be set up via PC only.

VectorRX Wireless Receivers

Systems with two VectorRX or VRX32-433 Receivers
can manage up to 64 Wireless Zones and up to 32
keyFobs (with two vectorRX-8 up to 16 Zones and up to
16 KeyFobs).
The Wireless Zones support the following Detectors:
Ø AMD10 - Wireless Pet-immune Infrared Detector
Ø AMC10 - Wireless Magnetic Contact
Ø AGB10 - Wireless Glass Break Detector
Ø ASD10 - Wireless Optical Smoke Detector
+
Wireless Devices other than those listed above are
not supported by the VectorRX Receiver. Read
the "APPENDIX" for further information on the
listed Devices.
The system can detect Alarm, Tamper, Low Battery and
Lost Wireless Detectors.
When a Wireless Detector (assigned to a Wireless
Zone) detects Alarm conditions, the system will gener-
Figure 28 AND Zones Page