Last exit Violation of a Last Exit Zone — during the
Exit Time of its Partition — will not generate any Events
but will clear any residual Exit Time, and trigger the
programmed Last Exit Time of its Partition.
In all other cases, the system will generate the Events
associated with the Instant Zones.
This feature will allow the system to Arm as soon as the
programmed Last Exit Time expires.
The last Zone leading out of a Partition should be pro -
grammed as a Last Exit Zone.
24h Violation of a 24h Zone — regardless of the status
of its Partition (Armed/Disarmed) will generate the fol -
lowing events:
Ø Alarm on zone (relevant to the Zone concerned);
Ø 24h alarm on partition, Generic alarm on partition
and Generic+Tamper alarm on partition — rele -
vant to the Partition the Zone is assigned to;
Ø Tamper alarm on panel, Generic alarm on panel
and Generic+Tamper alarm on panel.
24h Zones NEED NOT necessarily be assigned to Par -
titions. In which case, they will generate only:
Ø Alarm on zone (relevant to the Zone concerned);
24h Zones that are not assigned to Partitions can be used
for control applications, such as switching on courtesy
lights (using infrared sensors).
+
24h Zones which are not assigned to Partitions
must be programmed as Repetitive (refer to
"Cycles").
Fire Violation of a Fire Zone — regardless of the sta -
tus of its Partition (Armed/Disarmed) will generate the
following events:
Ø Alarm on zone (relevant to the Zone concerned);
Ø Fire alarm on partition, Generic alarm on parti -
tion and Generic+Tamper alarm on partition —
relevant to the Partition the Zone is assigned to;
Ø Fire alarm on panel, Generic alarm on panel and
Generic+Tamper alarm on panel.
Duress Violation of an Unbypassed Duress Zone which
is not in Test status, and has not run its programmed cy -
cles will generate the following Instant Events
Ø Alarm on zone (relevant to the Zone concerned);.
Moreover, the Keypad:
Ø WILL NOT signal Alarms triggered by Duress Zones
(the a indicator WILL NOT blink).
Ø WILL NOT signal outgoing calls triggered by Duress
Zones (X WILL NOT appear above the i icon).
n Command
If a Command Zone triggers an Alarm (see "Balance",
"Voltage Range" and "Sensitivity"), the system will gen-
erate the programmed Actions. In all other cases (Tam-
per and Short Circuit) it will operate as an Alarm Zone.
Command Zones will be active at all times, regardless
of the status of their Partitions (Armed/Disarmed).
KYO320
Arm/Disarm/Toggle If this command is enabled, all
the Partitions the Zone is assigned to will change status
when the Zone triggers an Alarm — Armed Partitions
will Disarm and visa versa (refer to "Partitions").
Arm/Disarm/Bistable If this command is enabled, all
the Partitions the Zone is assigned to will Arm — when
the Zone triggers an Alarm, and Disarm — when it re -
stores to standby.
+
Partitions — Armed by an Arm/Disarm/Bistable Com-
mand Zone — cannot be Disarmed until all the Zones
of that type are in standby status (and CANNOT be
Disarmed via Keypad, Reader, Telephone or PC).
Arm only If this command is enabled, all the Partitions
the Zone is assigned to will Arm when the Zone triggers
an Alarm.
Disarm only If this command is enabled, all the Parti-
tions the Zone is assigned to will Disarm when the Zone
triggers an Alarm.
Partition Reset If this command is enabled, all the
Partitions the Zone is assigned to will Reset when the
Zone triggers an Alarm.
Panel Reset If this command is enabled, the Control
panel will Reset when the Zone triggers an Alarm.
Clear Call Queue If this command is enabled, the Call
Queue will be cleared when the Zone triggers an Alarm.
n Attributes
+
The following attributes apply to Alarm Zones
ONLY.
Unbypassable Zones with this attribute cannot be By -
passed.
Chime Violation of a Zone with this attribute — during
Disarmed status of its Partition will generate the Chime
on partition no. event, and an audible signal (beep) on
the assigned Keypads. Violation of a Chime Zone —
7
:
during Armed status of its Partition will trigger the Ac -
tions programmed for the Type parameter.
+
The Chime Attribute is ineffective on 24h and Fire
Zones.
Test Violation of a Zone with this attribute will not
generate the Alarm on zone no. event. However, the
"Alarm - Zone under test" message will be recorded in
the Control panel log. The Test phase will allow you to
check the functionality of the Zones without triggering
Alarm signals. At default, the Control panel will record
ONLY the Events that occur during Armed status. How-
ever, by means of the respective option, events that oc-
cur during Disarmed status can also be recorded (refer
to the Options page).
PROGRAMMING
37