Active An Active Code can access and control the sys -
tem in accordance with its access level.
A Non-Active Code cannot access the system, however,
it can still be programmed using its Father Code.
Father Codes can toggle the Active status of their as -
signed Codes (also via the User Menu).
+
You cannot toggle the Active status of a Code that is
the sole Father of another Code.
AT Default: ONLY Code No. 001 is Active.
Duress Code If this option is enabled, any Telephone
actions (calls or reports) associated with the Recognized
user code event (generated by the Code concerned) will
not be signalled on the keypad (i.e. <@255> will not ap-
pear over the i icon).
Patrol Code If this option is enabled, the Code will be
able to perform Disarm and Arm operations ONLY, re-
gardless of its assigned Code Type. Furthermore, if a
Partition is Disarmed by a Code with the Patrol attribute,
it will remain Disarmed for the programmed Patrol
Time ONLY, after which, it will Rearm automatically
(refer to "Patrol Time" under "Partitions").
Father Code 1 - 2 - 3 This drop-down list will allow you
to select the Father codes.
Ø Each Code can have up to 3 Father codes;
Ø a Code can be programmed as its own Father.
A Father Code can:
Ø Change the PIN of its assigned Codes (Sons);
Ø Enable/Disable the Active status of its assigned
Codes, that is, if they are not Fathers of other Codes;
Ø Enable/Disable the Available status of its assigned
Codes.
+
YOU CANNOT assign a new Father code to a code
without first entering the PIN of one of its current Fa -
ther codes.
For KYO320 — Codes no. 132 to 195 (the 64 Tele -
phone Access Codes) CANNOT be Father codes.
Father codes can be changed by the User.
At default:
Ø Code no. 001 is its own Father code;
Ø Codes no. 002 to 131 have two Father codes: them-
selves and Code no. 001;
Ø Codes no. 132 to 195 have one Father code: Code no.
001.
KYO320
Linked event codes Connected with Code Types (if
Duress Code or not), in Contact ID and SIA protocol
case, the linked code changes. In this way, for exam -
ple, a code only will be automatically linked to a Du -
ress code.
n Enable on Partitions
The Enable on Partitions Table will allow you to se -
lect the Partitions the Code will be able to control and
set the A, B, C and D Arming modes, as follows.
Partitions The Partitions line (first line) shows the
Control Panel Partition ID Numbers.
+
If you click the Description button (at the bottom
of the page), the application will show the Parti-
tion Description.
The check boxes on the second line will allow you to
select the Code Partitions.
Ø Box ticked: the Code CAN operate on the corre-
sponding Partition.
Ø Box empty: the Code CANNOT operate on the cor-
responding Partition.
To DISABLE the Code on all the Partitions: click the
Partitions button (bottom of page) then select None.
To ENABLE the Code on all the Partitions: click the
Partitions button (bottom of page) then select All.
To toggle the current Enabled/Disabled status of the
Code: click Partitions button (bottom of page) then
select Invert selection.
+
Code commands will affect ONLY the Partitions
(and subsequently the Zones) common to both
the Code and Keypad in use.
A This line will allow you to select the A Mode Arming
configuration of the Partitions.
Double click on the Partition field until the required
mode is shown (D, N, A, S or I), or right click the Parti -
tion field then select the required mode from the
drop-down list.
Arming Modes
Ø D = Partition will Disarm
Ø N = no operation
Ø A = Partition will Arm in Away mode
Ø S = Partition will Arm in Stay mode
Ø I = Partition will Arm in Stay mode with zero delay
(Instant)
B As for A but for B Mode Arm commands at a Key -
pad.
C As for A but for C Mode Arm commands at a Key -
pad.
D As for A but for D Mode Arm commands at a Key -
pad.