The Wireless module option must be enabled
manually, otherwise, it will be impossible to pro-
gram the wireless devices (refer to "Wireless").
Transmission trouble between the Control Panel and
Receiver (due to Fault or Tamper) will be signalled by
an X above the s icon on the Keypad, and by the
Warning wireless device event.
+
Receiver Trouble and Lost BPI devices will be sig -
nalled in the same way ( X above the s icon on
the Keypad. If the signal is due to Receiver Trou -
ble, the Keypad will display the Receiver Lost
message in the TYPE field in the Events Log (refer
to "Events Log" in the KEYPAD PROGRAMMING
MANUAL).
Disable the Present option to clear the Receiver Trou -
ble warnings.
Time Supervision Zones This programming field will
allow you to program the supervisory time for the Su -
pervised Wireless Zones (refer to "Supervised" under
"Wireless" ). Each wireless zone should send a supervi -
sory signal within a programmed interval. If the Re -
ceiver does not receive the signal it will generate a Lost
wireless zone event.
Valid entries: 2 hours and 30 minutes (at default) to 24
hours (in 15-minute steps).
Zone control time Set this option for the Supervised
Wireless Zones ONLY(refer to "Supervised" under
"Wireless" ). When the Zone control time is elapsed
from when the Receiver has received the signal that
Each wireless zone should send the control panel
does not allow the arming if the "Disable arming on wire -
less zones fault" option is enable (See Option, page 75).
Valid entries: 15 minutes (at default) to 2 hours (in
15-minute steps). When a LCD keypad is arming, the
zones, that haven't sent signals in the programmed time
(Wireless delinquency Zones), are shown.
GSM Communicator Not present-Present-FUTURE
USE.
Disable Jamming If the system detects RF jamming,
and this option is DISABLED (at default), it will be sig -
nalled by an X above the b icon on the Keypad, and by
the Tamper wireless device event.
+
Jamming and BPI Device Tamper will be signalled
by X above the b icon on the Keypad. Jamming
and Receiver Tamper will be signalled by the Tam -
per wireless device event. If the signal is due to
Receiver Tamper (jamming, opening or removal)
the WLS Tamper event will be logged.
VOX board The Control Panel will enrol the Voice
board as soon as it is connected to the Keybus. Trans-
5 If the Full Arming alarm option is enabled, ALL the Partitions the Zone is assigned to must be Armed.
If the Full Arming alarm option is disabled, AT LEAST ONE of the Partitions the Zone is assigned to must be
Armed.
KYO320
mission trouble between the Control panel and Voice
Board (due to Fault or Tamper) will be signalled on the
G LED (ON).
+
The G LED signals several different Trouble
events. If the signal is due to loss of the Voice
Board, the Keypad (in View Trouble Mode) will
show the Vox Board Lost message (refer to
"View Trouble Mode" in the USER'S MANUAL).
Disable the Present option to clear the Voice board
Trouble warnings.
Print Log If this option is enabled the Control panel will
printout the events as they occur (real-time printout).
+
This feature is provided by the optional K3/PRT2
Printer Interface (refer to "K3/PRT2 Printer Inter -
face" in the APPENDIX).
Only Enabled events can be printed (refer to "Log
— Event settings").
Add line feed Enable this option, if there are over -
lapped lines on the printout. Disable this option, if there
are empty lines between events.

Hardwired Zones

The hardwired Zones can be used for system monitor -
ing (Alarm Zones), or management (Control Zones).
Alarm Zones If Alarm conditions are detected, the
Alarm Zones will generate the respective event (refer to
"Type"). The Events-Action page will allow you to as -
sociate each event with one or more actions (activation
of Hornstrobes, Digital Communicator, Dialler, etc.).
The system cannot generate an Alarm event until the Par -
titions the Zone is assigned to Arm
+
This does not apply to 24h and Fire Zone events,
as these events do not depend on Partition status.
If the zone is NOT an Exit Delay or Last Exit Zone (re-
fer to "Type") the Control Panel will start monitoring as
soon as the Partitions the Zone is assigned to Arm
otherwise, it will start monitoring when the longest Exit
Time of the Armed Partitions the Zone is assigned to
ends (refer to "Partitions").
The system will generate an Alarm when the voltage on
the Zone terminal falls within the Alarm voltage range
(refer to "Voltage Ranges") for the programmed num-
ber of times and/or length of time (refer to "Sensitivity").
Each Alarm Zone can generate the Zone Alarm event
for the programmed number of times (refer to "Cycles").
Command Zones Each Command Zone can be pro-
grammed to activate one of the following actions:
PROGRAMMING
5
(refer to "Partitions").
5
,
35