11.7 Output Terminal Function

It can be assigned the function No. in the following table to parameter f130 to f138, f157, f158.
 Table of output terminal functions 1
Function
Code
No.
0
LL
1
LLN
2
UL
3
ULN
4
LOW
5
LOWN
6
RCH
7
RCHN
8
RCHF
9
RCHFN
10
FL
11
FLN
14
POC
15
POCN
16
POL
17
POLN
20
POH
21
POHN
11
22
POP
23
POPN
24
MOFF
25
MOFFN
26
UC
27
UCN
28
OT
29
OTN
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Function
Frequency lower limit
Inversion of frequency lower limit
Frequency upper limit
Inversion of frequency upper limit
Low-speed detection signal
Inversion of low-speed detection signal
Output frequency attainment signal
(acceleration/deceleration completed)
Inversion of output frequency attainment
signal
(inversion of acceleration/deceleration
completed)
Set frequency attainment signal
Inversion of set frequency attainment signal
Fault signal (trip output)
Inversion of fault signal (inversion of trip
output)
Over-current detection pre-alarm
Inversion of over-current detection pre-alarm
Overload detection pre-alarm
Inversion of overload detection pre-alarm
Overheat detection pre-alarm
Inversion of overheat detection pre-alarm
Overvoltage detection pre-alarm
Inversion of overvoltage detection pre-alarm
Power circuit undervoltage detection
Inversion of power circuit undervoltage
detection
Small current detection
Inversion of small current detection
Over-torque detection
Inversion of over-torque detection
Action
ON: Output frequency is more than 
OFF: Output frequency is or less
Inversion of LL
ON: Output frequency is or more
OFF: Output frequency is less than 
Inversion of UL
ON: Output frequency is  or more
OFF: Output frequency is less than 
Inversion of LOW
ON: Output frequency is within command frequency 

OFF: Output frequency is more than command frequency 

Inversion of RCH
ON: Output frequency is within ±
OFF: Output frequency is more than  ±
Inversion of RCHF
ON: Inverter tripped
OFF: Inverter not tripped
Inversion of FL
ON: Output current is  or more
OFF: Output current is less than 
Inversion of POC
ON: (%) or more of calculated value of overload
protection level
OFF: Less than (%) of calculated value of overload
protection level
Inversion of POL
ON: Approx. 95C or more of IGBT element
OFF: Less than approx. 95C of IGBT element (90C or less
after detection is turned on)
Inversion of POH
ON: Overvoltage limit in operation
OFF: Overvoltage detection canceled
Inversion of POP
ON: Power circuit undervoltage (moff) detected
OFF: Undervoltage detection canceled
Inversion of MOFF
ON: After output current comes to  or less, value of
less than + for  set time
OFF: Output current is more than 
(+ or more after detection turns on)
Inversion of UC
ON: After torque comes to  or more, value of more
than - for  set time
OFF: Torque is less than 
(-or less after detection turns on)
Inversion of OT
K-34
E6581611
Reference
5.4
6.5.1
7.2.2
6.5.2
7.2.2
6.5.3
7.2.2
6.29.2
5.6
7.2.2
6.19.5
6.29.13
6.29.7
6.29.10