Toshiba VF-S15 Instruction Manual page 81

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

60 Hz default setting (typ=2)
Setting typ to 2 sets the following parameters for base frequency 60 Hz use.
(The setting values of other parameters are not changed.)
• Maximum frequency (fh)
• Base frequency 1 (vl)
• VIA input point 2 frequency (f204) : 60Hz
• VIC input point 2 frequency (f219) : 60Hz
• Process upper limit (f367)
• Motor rated speed (f417)
Default setting 1 (typ = 3)
Setting typ to 3 will return parameters to the default settings (exclusive of some parameters).
● When 3 is set, init is displayed for a short time after the settings are configured, and then
Be aware that the following parameters do not return to the default settings even if typ=3 is set for
maintainability. (To initialize all parameters, set typ=13) 
• f109:Analog/logic input selection (VIA/VIB)
* Refer to "Communication manual" about parameter cxxx.
Trip record clear (typ = 4)
Setting typ to 4 initializes the past eight sets of recorded error history data.
● The parameter does not change.
Cumulative operation time clear (typ = 5)
Setting typ to 5 resets the cumulative operation time to the initial value (zero).
Initialization of type information (typ = 6)
Setting typ to 6 clears the trips when an etyp format error occurs. But if the  displayed, contact
your Toshiba distributor.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
disappears. Then the inverter is in standard motor mode. In this case, the trip history data is cleared.
•aul:Overload characteristic selection
•fmsl:Meter selection
•fm:Meter adjustment gain
•set:Checking the region setting
•f107:Analog input terminal selection
: 60Hz
• Upper limit frequency (ul)
: 60Hz
• Base frequency 2 (f170)
• VIB input point 2 frequency (f213) : 60Hz
• Automatic light-load high-speed operation
: 60Hz
frequency (f330)
-1
: 1710 min
• Communication command point 2 frequency
(f814)
•f470~f475:VIA/VIB/VIC input bias / gain
•f669:Logic output/pulse train output selection
•f681:Analog output signal selection
•f691:Inclination characteristic of analog output
•f692:Analog output bias
•f880:Free notes
D-11
E6581611
: 60Hz
: 60Hz
: 60Hz
: 60Hz
4