Toshiba VF-S15 Instruction Manual page 316

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents

Advertisement

 Protection parameters
Communication
Title
No.
0601

0602

0603


0604
0605


0607
0608

0609

0610

0611

0612

0613


0614
0615

0616

0618

0619

0620


0621
0625

0626

*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
*12: When f701=1, adjustment range is 100%=rated current, or 100%=200V(240V class)/ 400V(500V class).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Stall prevention
%
1/1
level 1
(A)
Inverter trip
-
retention selection
Emergency stop
-
selection
DC braking time
s
0.1/0.1
during emergency
stop
Output phase
-
failure detection
selection
Motor 150%
s
1/1
overload detection
time
Input phase failure
-
detection selection
Small current
%
1/1
detection hysteresis
Small current
-
trip/alarm selection
Small current
%
1/1
detection current
(A)
Small current
s
1/1
detection time
Detection of
-
output short-circuit
at start-up
Ground fault
-
detection selection
Over-torque
-
trip/alarm selection
Over-torque
%
1/0.01
detection level
Over-torque
s
0.1/0.1
detection time
Over-torque
%
1/0.01
detection hysteresis
Cooling fan
-
ON/OFF control
Cumulative
100
0.1/0.1
operation time
hours
(=10 hours)
alarm setting
Factory specific
-
coefficient 6A
Over-voltage stall
%
1/1
protection level
Adjustment range
10-199, *12
200 (disabled)
-
0: Cleared with power off
1: Retained with power off
-
0: Coast stop
1: Deceleration stop
2: Emergency DC braking
3: Deceleration stop (f515)
4: Quick deceleration stop
5: Dynamic quick deceleration stop
0.0-20.0
-
0: Disabled
1: At start-up (only one time after
power on)
2: At start-up (each time)
3: During operation
4: At start-up + during operation
5: Detection of cutoff on output side
10-2400
-
0: Disabled
1: Enabled
1-20
-
0: Alarm only
1: Tripping
0-150 *12
0-255
-
0: Each time (standard pulse)
1: Only one time after power on
(standard pulse)
2: Each time (short pulse)
3: Only one time after power on
(short pulse)
-
0: Disabled
1: Enabled
-
0: Alarm only
1: Tripping
0 (disabled)
1-250
0.0-10.0
0-100
-
0: ON/OFF control
1: Always ON
2-7: -
0.0-999.0
-
-
100-150
K-17
E6581611
Default
User
Reference
setting
setting
150
6.29.2
0
6.29.3
0
6.29.4
1.0
0
6.29.5
300
5.6
6.29.1
1
6.29.6
10
6.29.7
0
0
0
0
6.29.8
1
6.29.9
0
6.29.10
150
0.5
10
0
6.29.11
876.0
6.29.12
-
*3
*2
6.19.4
6.19.5
11