Save user setting parameters (typ = 7)
Setting typ to 7 saves the current settings of all parameters.
Load user setting parameters (typ = 8)
Setting typ to 8 loads parameter settings to (calls up) those saved by setting typ to 7.
* By setting typ to 7 or 8, you can use parameters as your own default parameters.
Cumulative fan operation time record clear (typ = 9)
Setting typ to 9 resets the cumulative operation time to the initial value (zero).
Set this parameter when replacing the cooling fan, and so on
4
Number of starting clear (typ = 12)
Setting typ to12 resets the number of starting to the initial value (zero).
Default setting 2 (typ = 13)
Set typ to 13 to return all parameters to their default settings.
When 13 is set, init is displayed for a short time after the settings are configured, and then
disappears. Then setup menu set is displayed. After reviewing the setup menu items, make a setup
menu selection. In this case, all parameters are returned to their defaults, and the trip history data is cleared.
(Refer to section 3.1)